beautypg.com

Keri Systems Doors.NET Manual User Manual

Page 201

background image

Doors.NET Reference Manual

- 201 -

Weight (In Enclosure)

l

4D - 5.00 Lbs (2.27 Kgs)

l

2D - 4.95 Lbs (2.25 Kgs)

Input Voltage

l

+ 12 VDC nom. (10 - 14 VDC)

Current Draw

l

4D - 650 mA typical

l

2D - 570 mA typical

Inputs

l

4D - 8, re-assignable: 4 - Door Contact Switch, 4 - Request to Exit, expandable to
up to 24 Inputs using optional

4x4 I/O module

l

2D - 4, re-assignable: 2 - Door Contact Switch, 2 - Request to Exit, expandable to
up to 24 Inputs using optional

4x4 I/O module

Outputs

l

1.0 amp (24 VDC max.) dry circuit

l

4D - 4, re-assignable, expandable to up to 20 Outputs using optional

4x4 I/O mod-

ule

l

2D - 2, re-assignable, expandable to up to 10 Outputs using optional

4x4 I/O mod-

ule

Buffer Capacity

l

50,000 Cardholders

l

10,000 Events

Temperature / Humidity

l

-40° F to 140° F

l

-40° C to 60° C

l

0-90% Non Condensing

Communication

l

To Server: TCP/IP 10/100 bus

l

Between Controllers: TCP/IP 10/100 bus

Lithium Battery

l

5 years Memory Retention