Page 195

background image

Doors.NET Reference Manual

- 195 -

3. Select a reader on the system from the Reader drop-down list.

4. Note that since trace events are grouped by the trace name, it must be unique. For

this reason, the Unique Trace Name is automatically created, so at this point you
simply have to click the Add Trace button and the trace becomes active imme-
diately.

Messages that are generated by this reader are displayed independently on the
trace grid similarly to Live Events.

5. Also similar to Live Events is the Field Chooser, which allows you to select which

columns and information is displayed for the events. Click the icon to the left of the
first column and then make your field selections.