ETC Congo Family v6.4.0 User Manual
Page 242
240
In Congo UDP allows you to use the Ethernet network to:
• Receive Congo specific Action Macros directly from another unit, without having to
first create a trigger and event.
• Send any proprietary string of data to another unit that can receive commands over
UDP
Function
Explanation
Default
value
Input Port
The Input Port Congo listens to
0
Output Port
The Output port Congo sends to 0
Output IPs
The Output IP(s) Congo sends
to, add multiple and separate
with semicolon ";".
0
OSC (6.3)
Open Sound Control (OSC) is a content format for messaging among computers, sound
synthesizers, and other multimedia devices. See
OSC Functionality
.
Function
Explanation
Default
value
Activate
Activate OSC
Off
Input Port
The Input Port Congo listens to
8000
Output Port
The Output port Congo sends to 7000
Output IPs
The Output IP(s) Congo sends
to, add multiple and separate
with semicolon ";".
-