Dimmer/device feedback log (6.2) – ETC Congo Family v6.4.0 User Manual
Page 171

169
Dimmer/Device Feedback Log (6.2)
The Dimmer/Device feedback log (Browser >About) will show all logged dimmer feedback
messages from:
- RDM (new in v6.2)
- CEM3 (new in v6.2)
- FDX (new in v6.2)
- CEM+
- Dimstat
Active errors are marked with red. A column “Type” will show the source of the error.
Features
• The Active column shows if the error is active or if it has been cleared. You can also
reset a known error (to get rid of the indication on the channel) by toggling the Active
field.
• Select one or more rows in the Dimmer Feedback Log and press DELETE to remove
them from the list.
• If general dimmer errors are active, there is a warning sign in the title bar (see
below).
In the Header bar on top of the screens, the warning sign indicator will show dimmer and/or
other faults in the format: General Errors/Dimmer Errors.