I n s t a l l a t i o n G u i d e

Unison

®

Heritage Receptacle Station

Unison

®

Receptacle Station Installation Guide

Page 1 of 3

Electronic Theatre Controls, Inc.

Corporate Headquarters

„

3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA

„

Tel +608 831 4116

„

Fax +608 836 1736

London, UK

„

Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK

„

Tel +44 (0)20 8896 1000

„

Fax +44 (0)20 8896 2000

Rome, IT

„

Via Ennio Quirino Visconti, 11, 00193 Rome, Italy

„

Tel +39 (06) 32 111 683

„

Fax +44 (0) 20 8752 8486

Holzkirchen, DE

„

Ohmstrasse 3, 83607 Holzkirchen, Germany

„

Tel +49 (80 24) 47 00-0

„

Fax +49 (80 24) 47 00-3 00

Hong Kong

„

Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong

„

Tel +852 2799 1220

„

Fax +852 2799 9325

Service: (Americas)

[email protected]

„

(UK)

[email protected]

„

(DE)

[email protected]

„

(Asia)

[email protected]

Web:

www.etcconnect.com

„

Copyright © 2008 ETC. All Rights Reserved.

„

Product information and specifications subject to change.

7181M2130

„

Rev A

„

Released 10/2008

Overview

The Unison Heritage Receptacle Station (UH1RS) provides
connection of Unison portable stations to the Paradigm
LinkConnect control network.

Installation

The Unison Heritage Receptacle Station may be installed into an
industry standard single gang backbox (provided by others) or a
single gang surface mounted backbox (sold separately and
available from ETC).

Installation should follow local codes and standard practices. All
control wiring should be installed and terminated by a qualified
technician and should follow standard wiring installation
practices. Leave approximately 10 inches (254mm) of wiring in
the backbox for connection and future service needs.

Receptacle Station wiring requirements include:

• Connection to the Echelon

®

LinkPower (LinkConnect) control network utilizing low voltage Class

II wiring. Wiring is topology free and polarity independent over Belden 8471 (or approved equal).
The total combined length of a LinkPower wire run may not exceed 1,640 feet (500m), with a
maximum distance of 1,312 feet (400m) between any two devices.

• Connection of two 16 AWG (1.5mm

2

) wires for Auxiliary power, 24 Vdc. Auxiliary Power is

required to power some portable stations through the receptacle station and is sourced from the
host Paradigm product.

• Connection of one 14 AWG (2.5mm

2

) ESD drain (ground) wire. Required when the control cable

is not installed in grounded metal conduit.

The Heritage Receptacle Station ships with a termination kit containing a LinkPower pigtail, Auxiliary
Power pigtail, ESD drain (ground) wire pigtail, spacers and all required connectors for installation.

Auxiliary power

pigtail

LinkPower

pigtail

Ground wire

pigtail

WAGO

Spacers