Parameter Description
Issue 01/06
MICROMASTER 440 Parameter List
90
6SE6400-5BB00-0BP0
ASPmax
100 %
10 V
V
x
100%
%
P0760
P0758
P0757
P0759
P0756 = 4, P0761 = 0
ASPmin
-10 V
4000 h
Index:
P0757[0] : Analog input 1 (ADC 1)
P0757[1] : Analog input 2 (ADC 2)
Note:
The ADC-linear characteristic is described by 4 coordinates, based on a two-point equation:
0757
P
0759
P
0758
P
0760
P
P0757
-
x
P0758
-
y
−
−
=
For calculations the point-gradient form (offset and gradient) is more advantageous:
0
y
x
m
y
+
⋅
=
The transformation between these two forms is given by:
0757
P
0759
P
0758
P
0760
P
m
−
−
=
0757
P
0759
P
0760
P
0757
P
0759
P
0758
P
y
0
−
⋅
−
⋅
=
For scaling of the input the value of y_max and x_min has to be determined. This is done by the following
equations:
0758
P
0760
P
0759
P
0758
P
0757
P
0760
P
x
in
m
−
⋅
−
⋅
=
0757
P
0759
P
0758
P
0760
P
)
x
x
(
y
min
max
max
−
−
⋅
−
=
x
y
1
y
0
x
min
y
2
x
max
y
max
y
m
P0760
P0758
P0757
x
1
P0759
x
2
Notice:
The value x2 of ADC scaling P0759 must be greater than the value x1 of ADC scaling P0757.
P0758[2]
Value y1 of ADC scaling
Min: -99999.9
CStat:
CUT
Datatype: Float Unit:
%
Def:
0.0
P-Group: TERMINAL
Active: first confirm
QuickComm.: No
Max: 99999.9
Sets value of Y1 in [%] as described in P0757 (ADC scaling)
Index:
P0758[0] : Analog input 1 (ADC 1)
P0758[1] : Analog input 2 (ADC 2)
Dependency:
Affects P2000 to P2003 (reference frequency, voltage, current or torque) depending on which setpoint is to
be generated.
Level
2