Parameter description issue 01/06 – Siemens 440 User Manual
Page 212
Parameter Description
Issue 01/06
MICROMASTER 440 Parameter List
212
6SE6400-5BB00-0BP0
P2159[3]
Threshold frequency f_3
Min: 0.00
CStat:
CUT
Datatype: Float Unit:
Hz
Def:
30.00
P-Group: ALARMS
Active: Immediately
QuickComm.: No
Max: 650.00
Threshold_3 for comparing frequency to thresholds.
Tconst. speed filt
0 ... 1000 [ms]
P2153.D (5)
Threshold freq f_3
0.00 ... 650.00 [Hz]
P2159.D ( 30.00)
Hyst . freq. f_hys
0.00 ... 10.00 [Hz]
P2150.D (3.00)
Delay time of f _3
0 ... 10000 [ms]
P2160.D (10)
Delay time of f _3
0 ... 10000 [ms]
P2160.D (10)
| f_act | <= f_3
| f_act | > f_3
T 0
T 0
f_act
r2198 Bit03
r2198 Bit02
| f_act | <= f_3
Threshold freq f_3
0.00 ... 650.00 [Hz]
P2159.D (30.00)
Hyst. freq. f_hys
0.00 ... 10.00 [Hz]
P2150.D (3.00)
0
1
{
0
1
{
| f_act | > f_3
r2169
Index:
P2159[0] : 1st. Drive data set (DDS)
P2159[1] : 2nd. Drive data set (DDS)
P2159[2] : 3rd. Drive data set (DDS)
P2160[3]
Delay time of threshold freq f_3
Min: 0
CStat:
CUT
Datatype: U16 Unit:
ms
Def:
10
P-Group: ALARMS
Active: Immediately
QuickComm.: No
Max: 10000
Delay time for comparing frequency to threshold f_3 (P2159).
Index:
P2160[0] : 1st. Drive data set (DDS)
P2160[1] : 2nd. Drive data set (DDS)
P2160[2] : 3rd. Drive data set (DDS)
Details:
See diagram in P2159 (threshold frequency f_3)
P2161[3]
Min. threshold for freq. setp.
Min: 0.00
CStat:
CUT
Datatype: Float Unit:
Hz
Def:
3.00
P-Group: ALARMS
Active: Immediately
QuickComm.: No
Max: 10.00
Minimum threshold value for comparing frequency setpoint.
0
1
{
0
1
{
0
Setp.min.threshold
0.00 ... 10.00 [Hz]
P2161.D (3.00)
Hyst . freq. f_hys
0.00 ... 10.00 [Hz]
P2150.D (3.00)
Hyst . freq. f_hys
0.00 ... 10.00 [Hz]
P2150.D (3.00)
| f_set | <= P2161
| f_set | <= P2161
f_set > 0
f_set > 0
f_set
r2198 Bit04
r2198 Bit05
Index:
P2161[0] : 1st. Drive data set (DDS)
P2161[1] : 2nd. Drive data set (DDS)
P2161[2] : 3rd. Drive data set (DDS)
Level
2
Level
2
Level
2