Parameter description issue 01/06 – Siemens 440 User Manual
Page 254
Parameter Description
Issue 01/06
MICROMASTER 440 Parameter List
254
6SE6400-5BB00-0BP0
P2873[2]
CI: SUB 1
Min: 0:0
CStat:
CUT
Datatype: U32 Unit:
-
Def:
755:0
P-Group: TECH
Active: first confirm
QuickComm.: No
Max: 4000:0
Define inputs of Subtracter 1, result is in P2874.
P2873
r2874
x
1
x
2
200%
-200%
x1 - x2
P2800 P2802[6]
x1 - x2 > 200%
→
x1 - x2 < -200%
→
Result = 200%
Result = -200%
Index 0
Index 1
Result = x1 - x2
If:
Result
Index:
P2873[0] : Connector input 0 (CI 0)
P2873[1] : Connector input 1 (CI 1)
Dependency:
P2802[6] is active level for the Subtracter.
r2874
CO: SUB 1
Min: -
Datatype: Float Unit:
%
Def:
-
P-Group: TECH
Max: -
Result of Subtracter 1.
Dependency:
P2802[6] is active level for the Subtracter.
P2875[2]
CI: SUB 2
Min: 0:0
CStat:
CUT
Datatype: U32 Unit:
-
Def:
755:0
P-Group: TECH
Active: first confirm
QuickComm.: No
Max: 4000:0
Define inputs of Subtracter 2, result is in P2876.
Index:
P2875[0] : Connector input 0 (CI 0)
P2875[1] : Connector input 1 (CI 1)
Dependency:
P2802[7] is active level for the Subtracter.
r2876
CO: SUB 2
Min: -
Datatype: Float Unit:
%
Def:
-
P-Group: TECH
Max: -
Result of Subtracter 2.
Dependency:
P2802[7] is active level for the Subtracter.
P2877[2]
CI: MUL 1
Min: 0:0
CStat:
CUT
Datatype: U32 Unit:
-
Def:
755:0
P-Group: TECH
Active: first confirm
QuickComm.: No
Max: 4000:0
Define inputs of Multiplier 1, result is in P2878.
r2878
x
1
x
2
200%
-200%
100%
x2
x1
∗
> 200%
→
< -200%
→
%
100
2
x
1
x
%
100
2
x
1
x
∗
∗
Result = 200%
Result = -200%
If:
P2877
Index 0
Index 1
%
100
2
x
1
x
∗
P2800 P2802[8]
Result =
Result
Index:
P2877[0] : Connector input 0 (CI 0)
P2877[1] : Connector input 1 (CI 1)
Dependency:
P2802[8] is active level for the Multiplier.
r2878
CO: MUL 1
Min: -
Datatype: Float Unit:
%
Def:
-
P-Group: TECH
Max: -
Result of Multiplier 1.
Dependency:
P2802[8] is active level for the Multiplier.
Level
3
Level
3
Level
3
Level
3
Level
3
Level
3