Parameter description issue 01/06 – Siemens 440 User Manual
Page 52

Parameter Description
Issue 01/06
MICROMASTER 440 Parameter List
52
6SE6400-5BB00-0BP0
NEMA Motor
T
1
T
4
T
7
T
3
T
6
T
9
T
8
T
5
T
2
Volts
U
V
W
T
1
-T
7
T
2
-T
8
T
3
-T
9
low
T
4
-T
5
-T
6
T
1
T
2
T
3
high
Connected
together
Connection
T
1
-T
7
T
2
-T
8
T
3
-T
9
Y Y
Y
U
V
W
T
1
-T
6
-T
7
T
2
-T
4
-T
8
T
3
-T
5
-T
9
-
T
1
T
2
T
3
T
4
-T
7
T
5
-T
8
T
6
-T
9
∆ ∆
∆
T
1
T
4
T
7
T
2
T
5
T
8
T
3
T
9
T
6
e.g.: Volts 230 V YY (low) / 460 V Y (high)
Volts
low
high
Connected
together
Connection
P0305[3]
Rated motor current
Min: 0.01
CStat:
C
Datatype: Float Unit:
A
Def:
3.25
P-Group: MOTOR
Active: first confirm
QuickComm.: Yes Max: 10000.00
Nominal motor current [A] from rating plate - see diagram in P0304.
Index:
P0305[0] : 1st. Drive data set (DDS)
P0305[1] : 2nd. Drive data set (DDS)
P0305[2] : 3rd. Drive data set (DDS)
Dependency:
-
Changeable only when P0010 = 1 (quick commissioning).
-
Default value is depending on inverter type and its rating data.
-
Depends also on P0320 (motor magnetization current).
Note:
The maximum value of P0305 depends on the maximum inverter current r0209 and the motor type:
Synchronous motor :
r0209
2
=
P0305
syn
max,
⋅
Asynchronous motor :
r0209
=
P0305
asyn
max,
It is recommanded that the ratio of P0305 (rated motor current) and r0207 (rated inverter current) should not
be lower than:
U/f :
SLVC and VC :
r0207
P0305
8
1
≤
r0207
P0305
4
1
≤
P0307[3]
Rated motor power
Min: 0.01
CStat:
C
Datatype: Float Unit:
-
Def:
0.12
P-Group: MOTOR
Active: first confirm
QuickComm.: Yes Max: 2000.00
Nominal motor power [kW/hp] from rating plate.
Index:
P0307[0] : 1st. Drive data set (DDS)
P0307[1] : 2nd. Drive data set (DDS)
P0307[2] : 3rd. Drive data set (DDS)
Dependency:
-
If P0100 = 1, values will be in [hp] - see diagram P0304 (rating plate).
-
Changeable only when P0010 = 1 (quick commissioning).
-
Default value is depending on inverter type and its rating data.
Level
1
Level
1