Siemens 440 User Manual
Page 40
Parameter Description
Issue 01/06
MICROMASTER 440 Parameter List
40
6SE6400-5BB00-0BP0
r0075
CO: Current setpoint Isd
Min: -
Datatype: Float Unit:
A
Def:
-
P-Group: CONTROL
Max: -
Displays setpoint of flux generating current component.
Dependency:
Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value
zero.
r0076
CO: Act. current Isd
Min: -
Datatype: Float Unit:
A
Def:
-
P-Group: CONTROL
Max: -
Displays flux generating current component.
Dependency:
Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value
zero.
r0077
CO: Current setpoint Isq
Min: -
Datatype: Float Unit:
A
Def:
-
P-Group: CONTROL
Max: -
Displays setpoint for component of torque generating current.
Dependency:
Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value
zero.
r0078
CO: Act. current Isq
Min: -
Datatype: Float Unit:
A
Def:
-
P-Group: CONTROL
Max: -
Displays component of torque generating current.
r0079
CO: Torque setpoint (total)
Min: -
Datatype: Float Unit:
Nm
Def:
-
P-Group: CONTROL
Max: -
Displays total torque setpoint.
Dependency:
Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value
zero.
r0080
CO: Act. torque
Min: -
Datatype: Float Unit:
Nm
Def:
-
P-Group: CONTROL
Max: -
Displays actual torque. Output value will be zero at low frequencies when current injection is active (r1751.5
= 1).
r0084
CO: Act. air gap flux
Min: -
Datatype: Float Unit:
%
Def:
-
P-Group: CONTROL
Max: -
Displays air gap flux in [%] relative to the rated motor flux.
r0086
CO: Act. active current
Min: -
Datatype: Float Unit:
A
Def:
-
P-Group: CONTROL
Max: -
Displays active (real part) of motor current.
Dependency:
Applies when V/f control is selected in P1300 (control mode); otherwise, the display shows the value zero.
r0090
CO: Act. rotor angle
Min: -
Datatype: Float Unit:
°
Def:
-
P-Group: CONTROL
Max: -
Indicates the current angle of the rotor. This function is not available on single input channel encoders.
Level
3
Level
3
Level
3
Level
3
Level
3
Level
4
Level
4
Level
3
Level
2