Siemens 440 User Manual
Page 74
Parameter Description
Issue 01/06
MICROMASTER 440 Parameter List
74
6SE6400-5BB00-0BP0
r0633[3]
CO: Rotor winding temperature
Min: -
Datatype: Float Unit:
°C
Def:
-
P-Group: MOTOR
Max: -
Displays rotor winding temperature of motor mass model.
Index:
r0633[0] : 1st. Drive data set (DDS)
r0633[1] : 2nd. Drive data set (DDS)
r0633[2] : 3rd. Drive data set (DDS)
P0640[3]
Motor overload factor [%]
Min: 10.0
CStat:
CUT
Datatype: Float Unit:
%
Def:
150.0
P-Group: MOTOR
Active: Immediately
QuickComm.: Yes Max: 400.0
Defines motor overload current limit in [%] relative to P0305 (rated motor current).
Index:
P0640[0] : 1st. Drive data set (DDS)
P0640[1] : 2nd. Drive data set (DDS)
P0640[2] : 3rd. Drive data set (DDS)
Dependency:
Limited to maximum inverter current or to 400 % of rated motor current (P0305), whichever is the lower.
100
P0305
P0305)
4
(r0209,
min
P0640
max
⋅
⋅
=
Details:
See function diagram for current limitation.
Level
4
Level
2