beautypg.com

Siemens 440 User Manual

Page 74

background image

Parameter Description

Issue 01/06

MICROMASTER 440 Parameter List

74

6SE6400-5BB00-0BP0

r0633[3]

CO: Rotor winding temperature

Min: -

Datatype: Float Unit:

°C

Def:

-

P-Group: MOTOR

Max: -

Displays rotor winding temperature of motor mass model.

Index:

r0633[0] : 1st. Drive data set (DDS)
r0633[1] : 2nd. Drive data set (DDS)
r0633[2] : 3rd. Drive data set (DDS)

P0640[3]

Motor overload factor [%]

Min: 10.0

CStat:

CUT

Datatype: Float Unit:

%

Def:

150.0

P-Group: MOTOR

Active: Immediately

QuickComm.: Yes Max: 400.0

Defines motor overload current limit in [%] relative to P0305 (rated motor current).

Index:

P0640[0] : 1st. Drive data set (DDS)
P0640[1] : 2nd. Drive data set (DDS)
P0640[2] : 3rd. Drive data set (DDS)

Dependency:

Limited to maximum inverter current or to 400 % of rated motor current (P0305), whichever is the lower.

100

P0305

P0305)

4

(r0209,

min

P0640

max

=

Details:

See function diagram for current limitation.

Level

4

Level

2