Parameter Description
Issue 01/06
MICROMASTER 440 Parameter List
194
6SE6400-5BB00-0BP0
P2002[3] Reference
current
Min: 0.10
CStat:
CT
Datatype: Float Unit:
A
Def:
0.10
P-Group: COMM
Active: first confirm
QuickComm.: No
Max: 10000.00
Full-scale output current used over serial link (corresponds to 4000H).
Index:
P2002[0] : 1st. Drive data set (DDS)
P2002[1] : 2nd. Drive data set (DDS)
P2002[2] : 3rd. Drive data set (DDS)
Example:
If a BICO connection is made between two parameters, the "unit" of the parameters (standardized (Hex) or
physical (i.e. A) values) may differ. MICROMASTER implicitly makes an automatic conversion to the target
value.
P2016
[0]
[1]
[2]
[3]
r0027
x[A]
y[Hex]
]
Hex
[
4000
P2002[A]
r0027[A]
y[Hex]
⋅
=
USS-PZD
BOP link
P2003[3] Reference
torque
Min: 0.10
CStat:
CT
Datatype: Float Unit:
Nm
Def:
0.12
P-Group: COMM
Active: first confirm
QuickComm.: No
Max: 99999.00
Full-scale reference torque used over the serial link (corresponds to 4000H).
Index:
P2003[0] : 1st. Drive data set (DDS)
P2003[1] : 2nd. Drive data set (DDS)
P2003[2] : 3rd. Drive data set (DDS)
Example:
If a BICO connection is made between two parameters or alternatively using P1500, the "unit" of the
parameters (standardized (Hex) or physical (i.e. Nm) values) may differ. MICROMASTER implicitly makes
an automatic conversion to the target value.
P2051
[0]
CB-PZD
COM link
[1]
[2]
[3]
r0080
x[Nm]
y[Hex]
]
Hex
[
4000
P2003[Nm]
r0080[Nm]
y[Hex]
⋅
=
P2004[3] Reference
power
Min: 0
CStat:
CT
Datatype: Float Unit:
-
Def:
P-Group: COMM
Active: first confirm
QuickComm.: No
Max: 0
Full-scale reference power used over the serial link (corresponds to 4000H).
P2003
P2000
M
f
2
2
1
r2004
⋅
⋅
π
=
⋅
⋅
π
⋅
⋅
=
Index:
P2004[0] : 1st. Drive data set (DDS)
P2004[1] : 2nd. Drive data set (DDS)
P2004[2] : 3rd. Drive data set (DDS)
Example:
If a BICO connection is made between two parameters, the "unit" of the parameters (standardized (Hex) or
physical (i.e. kW / hp) values) may differ. MICROMASTER implicitly makes an automatic conversion to the
target value.
P2019
[0]
USS
COM link
[1]
[2]
[3]
r0032
x[kW]
y[Hex]
]
Hex
[
4000
r2004
r0032
y[Hex]
⋅
=
or
x[hp]
depending on P0100
Level
3
Level
3
Level
3