Parameter Description

Issue 01/06

MICROMASTER 440 Parameter List

124

6SE6400-5BB00-0BP0

P1060[3]

JOG ramp-up time

Min: 0.00

CStat:

CUT

Datatype: Float Unit:

s

Def:

10.00

P-Group: SETPOINT

Active: first confirm

QuickComm.: No

Max: 650.00

Sets jog ramp-up time. This is the time used while jogging is active.

f (Hz)

t (s)

f max

(P1082)

P1060

t

up

P1060

P1082

1058

P

t

up

=

P1058

0

JOG

Index:

P1060[0] : 1st. Drive data set (DDS)
P1060[1] : 2nd. Drive data set (DDS)
P1060[2] : 3rd. Drive data set (DDS)

Notice:

Ramp times will be used as follows:
-

P1060 / P1061 : JOG mode is active

-

P1120 / P1121 : Normal mode (ON/OFF) is active

-

P1060 / P1061 : Normal mode (ON/OFF) and P1124 is active

P1061[3] JOG

ramp-down

time

Min: 0.00

CStat:

CUT

Datatype: Float Unit:

s

Def:

10.00

P-Group: SETPOINT

Active: first confirm

QuickComm.: No

Max: 650.00

Sets ramp-down time. This is the time used while jogging is active.

f (Hz)

t (s)

f max

(P1082)

P1061

P1082

1058

P

t

down

=

P1061

t

down

JOG

P1058

0

Index:

P1061[0] : 1st. Drive data set (DDS)
P1061[1] : 2nd. Drive data set (DDS)
P1061[2] : 3rd. Drive data set (DDS)

Notice:

Ramp times will be used as follows:
-

P1060 / P1061 : JOG mode is active

-

P1120 / P1121 : Normal mode (ON/OFF) is active

-

P1060 / P1061 : Normal mode (ON/OFF) and P1124 is active