Parameter description issue 01/06 – Siemens 440 User Manual
Page 60

Parameter Description
Issue 01/06
MICROMASTER 440 Parameter List
60
6SE6400-5BB00-0BP0
P0352[3] Cable
resistance
Min: 0.0
CStat:
CUT
Datatype: Float Unit:
Ohm
Def:
0.0
P-Group: MOTOR
Active: Immediately
QuickComm.: No
Max: 120.0
Describes cable resistance between inverter and motor for one phase.
d
M
l
l : Cable length
d : Cable diameter
A : Cable cross-section
: Specific resistance
ρ
A
l
R
⋅
ρ
=
2
2
d
A
⋅
π
=
m
mm
0,0178
2
Cu
⋅
Ω
=
ρ
Inverter
Index:
P0352[0] : 1st. Drive data set (DDS)
P0352[1] : 2nd. Drive data set (DDS)
P0352[2] : 3rd. Drive data set (DDS)
P0354[3] Rotor
resistance
Min: 0.0
CStat:
CUT
Datatype: Float Unit:
Ohm
Def:
10.0
P-Group: MOTOR
Active: Immediately
QuickComm.: No
Max: 300.0
Sets rotor resistance of motor equivalent circuit (phase value).
Index:
P0354[0] : 1st. Drive data set (DDS)
P0354[1] : 2nd. Drive data set (DDS)
P0354[2] : 3rd. Drive data set (DDS)
Dependency:
Calculated automatically using the motor model or determined using P1910 (motor identification).
P0356[3]
Stator leakage inductance
Min: 0.00001
CStat:
CUT
Datatype: Float Unit:
-
Def:
10.00000
P-Group: MOTOR
Active: Immediately
QuickComm.: No
Max: 1000.00000
Sets stator leakage inductance [mH] of motor equivalent circuit (phase value).
1000
0356
P
0310
P
2
L
f
2
L
X
S
S
S
⋅
⋅
π
⋅
=
⋅
⋅
π
⋅
=
⋅
ω
=
σ
σ
σ
Stator leakage reactance:
Index:
P0356[0] : 1st. Drive data set (DDS)
P0356[1] : 2nd. Drive data set (DDS)
P0356[2] : 3rd. Drive data set (DDS)
Dependency:
Calculated automatically using the motor model or determined using P1910 (motor identification).
P0358[3]
Rotor leakage inductance
Min: 0.0
CStat:
CUT
Datatype: Float Unit:
-
Def:
10.0
P-Group: MOTOR
Active: Immediately
QuickComm.: No
Max: 1000.0
Sets rotor leakage inductance [mH] of motor equivalent circuit (phase value).
1000
0358
P
0310
P
2
L
f
2
L
X
R
R
R
⋅
⋅
π
⋅
=
⋅
⋅
π
⋅
=
⋅
ω
=
σ
σ
σ
Rotor leakage reactance:
Index:
P0358[0] : 1st. Drive data set (DDS)
P0358[1] : 2nd. Drive data set (DDS)
P0358[2] : 3rd. Drive data set (DDS)
Dependency:
Calculated automatically using the motor model or determined using P1910 (motor identification).
Level
3
Level
4
Level
4
Level
4