beautypg.com

3 parameter description, 1 common parameters – Siemens 440 User Manual

Page 25

background image

Issue 01/06

Parameter Description

MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0

25

3 Parameter

Description

Note
Level 4 Parameters are not visible with BOP or AOP.

3.1 Common

parameters

r0000 Drive

display

Min: -

Datatype: U16 Unit:

-

Def:

-

P-Group: ALWAYS

Max: -

Displays the user selected output as defined in P0005.

Note:

Pressing the "Fn" button for 2 seconds allows the user to view the values of DC link voltage, output
frequency, output voltage, output current, and chosen r0000 setting (defined in P0005).

r0002 Drive

state

Min: -

Datatype: U16 Unit:

-

Def:

-

P-Group: COMMANDS

Max: -

Displays actual drive state.

Possible Settings:

0 Commissioning

mode

(P0010

!=

0)

1 Drive

ready

2

Drive fault active

3

Drive starting (DC-link precharging)

4 Drive

running

5

Stopping (ramping down)

Dependency:

State 3 visible only while precharging DC link, and when externally powered communications board is fitted.

P0003 User

access

level

Min: 0

CStat:

CUT

Datatype: U16 Unit:

-

Def:

1

P-Group: ALWAYS

Active: first confirm

QuickComm.: No

Max: 4

Defines user access level to parameter sets. The default setting (standard) is sufficient for most simple
applications.

Possible Settings:

0

User defined parameter list - see P0013 for details on use

1

Standard: Allows access into most frequently used parameters.

2

Extended: Allows extended access e.g. to inverter I/O functions.

3

Expert: For expert use only.

4

Service: Only for use by authorized service personal - password protected.

P0004 Parameter

filter

Min: 0

CStat:

CUT

Datatype: U16 Unit:

-

Def:

0

P-Group: ALWAYS

Active: first confirm

QuickComm.: No

Max: 22

Filters available parameters according to functionality to enable a more focussed approach to
commissioning.

Possible Settings:

0 All

parameters

2 Inverter
3 Motor
4 Speed

sensor

5

Technol. application / units

7

Commands, binary I/O

8

ADC and DAC

10 Setpoint channel / RFG
12 Drive

features

13 Motor

control

20 Communication
21 Alarms / warnings / monitoring
22 Technology controller (e.g. PID)

Example:

P0004 = 22 specifies that only PID parameters will be visible.

Level

1

Level

2

Level

1

Level

1