Siemens 440 User Manual
Page 178

Parameter Description
Issue 01/06
MICROMASTER 440 Parameter List
178
6SE6400-5BB00-0BP0
r1527
CO: Lower torque limitation
Min: -
Datatype: Float Unit:
Nm
Def:
-
P-Group: CONTROL
Max: -
Displays actual lower torque limitation.
Details:
See parameter r1526.
P1530[3]
Motoring power limitation
Min: 0.00
CStat:
CUT
Datatype: Float Unit:
-
Def:
0.12
P-Group: CONTROL
Active: Immediately
QuickComm.: No
Max: 8000.00
Defines fixed value for the max. permissible motoring active power (motoring power limitation).
P1530
def
P1530
max
0307
P
3
⋅
=
0307
P
5
.
2
⋅
=
Parameter P1530 limits the torque in addition to the act. frequency as displayed in the following
characteristic.
M
f
f
2
P
M
⋅
π
⋅
=
Power limitation (motoring, regenerative)
P1530
P1531
P1530
P1531
Index:
P1530[0] : 1st. Drive data set (DDS)
P1530[1] : 2nd. Drive data set (DDS)
P1530[2] : 3rd. Drive data set (DDS)
P1531[3]
Regenerative power limitation
Min: -8000.00
CStat:
CUT
Datatype: Float Unit:
-
Def:
-0.12
P-Group: CONTROL
Active: Immediately
QuickComm.: No
Max: 0.00
Enters fixed value for the max. permissible regenerative active power (regenerative power limitation).
P1531
max
P0307
3
-
⋅
=
P1531
def
P0307
2.5
-
⋅
=
Index:
P1531[0] : 1st. Drive data set (DDS)
P1531[1] : 2nd. Drive data set (DDS)
P1531[2] : 3rd. Drive data set (DDS)
Details:
See parameter P1530.
r1536
CO: Max. trq. motoring current
Min: -
Datatype: Float Unit:
A
Def:
-
P-Group: CONTROL
Max: -
Displays maximum torque motoring current component.
r1537
CO: Max trq regenerative current
Min: -
Datatype: Float Unit:
A
Def:
-
P-Group: CONTROL
Max: -
Displays maximum torque of the regenerative current component.
Level
3
Level
2
Level
2
Level
4
Level
4