Issue 01/06 function diagrams – Siemens 440 User Manual
Page 281

Issue 01/06
Function Diagrams
MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0
281
- 4150 -
F
unc
tion di
agr
am
8
7
6
5
4
3
2
1
415
0_S
TW1
.v
sd
T
ec
hnol
ogy
F
un
cti
ons
M
IC
R
O
M
AST
ER
440
16.01
.2
006
V
2.1
Control w
ord 1
(r
0054)
1)
(1
:0
)
BI: 1. OF
F2
P0844.C
(1
9:1)
BI: 2. OF
F2
P0845.C
(1:
0)
B
I: Pul
se ena
bl
ing
P0852.C
(1:
0)
BI: R
F
G enable
P1140.C
(1:
0)
BI: R
F
G start
P1141.C
(1:
0)
BI:R
FG enable setp
P1142.C
1
(722:2)
BI:
1. Fau
lts ackn
P2103.C
(0
:0
)
BI:
2. Fau
lts ackn
P2104.C
(0:
0)
B
I: Enable J
OG -
>
P1055.C
(0:
0)
B
I: Enable J
OG <
-
P1056.C
(19:1
3)
BI: Enable MOP(U
P
)
P1035.C
(19:1
4)
BI:Enable MOP(
DWN)
P1036.C
(0:
0)
BI: C
D
S b0 loc/rem
P0810
T
he sequence contr
ol
is the inter
nal
contr
ol
(
softwar
e) f
or r
eali
zing the
inverter
status (r
0001)
CO/BO
: A
ct
C
trlWd1
r005
4
r005
4
Sequence contr
ol
1
)
Braking contro
l
Setpoint channel
Sequence contr
ol
1
)
Braking contro
l
Sequence contr
ol
1
)
Braking contro
l
Setpoint channel
Sequence contr
ol
1
)
Sequence contr
ol
1
)
Setpoint channel
Setpoint channel
Setpoint channel
Sequence contr
ol
1
)
Setpoint channel
Sequence contr
ol
1
)
Setpoint channel
Setpoint channel
Setpoint channel
Setpoint channel
Sequence contr
ol
1
)
Note:T
his
bit must be
s
et
in
th
e fi
rs
t PZD
wor
d of the
tel
eg
ram r
ecei
ved f
rom ser
ial inter
fac
e
s,
so
th
at the converte
r will
a
ccept th
e process data as being
va
lid (compa
re U
S
S,
P
R
OFIBUS,
etc
.)
BOP/AO
P via "
F
n"
1 0
3
2
5 4
7 6
9 8
11
10
13 12
15 1
4
Segme
nt Bi
t
Segme
nt Bi
t
Seve
n-
segm
en
t d
ispla
y
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
Bit
No.
(722:0)
BI: ON/OFF
1
P08
40.C
(0:0)
BI
:O
N
re
ve
rs
e/
OF
F1
P08
42.C
1
(1
:0
)
BI: 1. OF
F3
P0848.C
(1
:0
)
BI: 2. OF
F3
P0849.C
(0:0)
BI
:O
N
re
ve
rs
e/
OF
F1
P08
42.C
(722:1)
BI: Rever
se
P11
13.C
1
All bi
ts =
1 -
->
dr
iv
e r
uns
Mea
n
in
g
0
= ON
/O
F
F
1
, Shutdown
v
ia r
amp, followed b
y pu
ls
e disabl
e
1
= ON
, opera
tin
g
c
on
di
tion (
edge-
co
ntrolled)
0
= OF
F2: Electrical s
top
, puls
e d
isable, moto
r coasts down
1
= Oper
ating conditi
o
n
0
= OFF
3: Fast stop
1
= Oper
ating conditi
o
n
Para
m
eter r00
54
1
= Pulse enable
0
= Pulse dis
a
bl
e
1
= R
F
G enab
le
0 =
S
et R
F
G
to
0
1 =
RF
G
s
ta
rt
0 =
S
top
R
F
G
1
= R
F
G setpoint enab
le
0
= Set
poi
n
t di
sable
0 =
No
1
= F
ault ack
n
owledge
0 =
NO
1
= JOG r
ight
0 =
NO
1
= JOG l
ef
t
1
= C
ontr
ol
fr
om PLC
0
= N
o contro
l fr
om PLC
1
= R
everse (
setp
oi
nt
in
ver
sion)
0
= R
evers dis
a
bl
ed
re
se
rv
ed
0 =
NO
1
= M
otor p
otentiometer
MOP up
0 =
NO
1
= M
otor p
otentiometer
MOP down
0 =
NO
1
= C
D
S Bit 0 (local/rem
ote)
&
&