Parameter description issue 01/06, P0201 power stack code number, R0203 act. inverter type – Siemens 440 User Manual
Page 44

Parameter Description
Issue 01/06
MICROMASTER 440 Parameter List
44
6SE6400-5BB00-0BP0
Code-
No.
MM440
MLFB
Input Voltage & Frequency
CT Power
kW
VT Power
kW
Internal
Filter
Frame
Size
94 6SE6440-2AD25-5CAx 3AC380-480V +10% -10% 47-63Hz
5,5
7,5 Cl. A
C
95 6SE6440-2AD27-5CAx 3AC380-480V +10% -10% 47-63Hz
7,5
11 Cl. A
C
96 6SE6440-2AD31-1CAx 3AC380-480V +10% -10% 47-63Hz
11
15 Cl. A
C
97 6SE6440-2UD31-5DAx
3AC380-480V +10% -10% 47-63Hz
15
18,5 no
D
98 6SE6440-2UD31-8DAx
3AC380-480V +10% -10% 47-63Hz
18,5
22 no
D
99 6SE6440-2UD32-2DAx
3AC380-480V +10% -10% 47-63Hz
22
30 no
D
100 6SE6440-2AD31-5DAx 3AC380-480V +10% -10% 47-63Hz
15
18,5 Cl. A
D
101 6SE6440-2AD31-8DAx 3AC380-480V +10% -10% 47-63Hz
18,5
22 Cl. A
D
102 6SE6440-2AD32-2DAx 3AC380-480V +10% -10% 47-63Hz
22
30 Cl. A
D
103 6SE6440-2UD33-0EAx
3AC380-480V +10% -10% 47-63Hz
30
37 no
E
104 6SE6440-2UD33-7EAx
3AC380-480V +10% -10% 47-63Hz
37
45 no
E
105 6SE6440-2AD33-0EAx
3AC380-480V +10% -10% 47-63Hz
30
37 Cl. A
E
106 6SE6440-2AD33-7EAx
3AC380-480V +10% -10% 47-63Hz
37
45 Cl. A
E
107 6SE6440-2UD34-5FAx
3AC380-480V +10% -10% 47-63Hz
45
55 no
F
108 6SE6440-2UD35-5FAx
3AC380-480V +10% -10% 47-63Hz
55
75 no
F
109 6SE6440-2UD37-5FAx
3AC380-480V +10% -10% 47-63Hz
75
90 no
F
110 6SE6440-2AD34-5FAx
3AC380-480V +10% -10% 47-63Hz
45
55 Cl. A
F
111 6SE6440-2AD35-5FAx
3AC380-480V +10% -10% 47-63Hz
55
75 Cl. A
F
112 6SE6440-2AD37-5FAx
3AC380-480V +10% -10% 47-63Hz
75
90 Cl. A
F
113 6SE6440-2UE17-5CAx
3AC500-600V +10% -10% 47-63Hz
0,75
1,5 no
C
114 6SE6440-2UE21-5CAx
3AC500-600V +10% -10% 47-63Hz
1,5
2,2 no
C
115 6SE6440-2UE22-2CAx
3AC500-600V +10% -10% 47-63Hz
2,2
4 no
C
116 6SE6440-2UE24-0CAx
3AC500-600V +10% -10% 47-63Hz
4
5,5 no
C
117 6SE6440-2UE25-5CAx
3AC500-600V +10% -10% 47-63Hz
5,5
7,5 no
C
118 6SE6440-2UE27-5CAx
3AC500-600V +10% -10% 47-63Hz
7,5
11 no
C
119 6SE6440-2UE31-1CAx
3AC500-600V +10% -10% 47-63Hz
11
15 no
C
120 6SE6440-2UE31-5DAx
3AC500-600V +10% -10% 47-63Hz
15
18,5 no
D
121 6SE6440-2UE31-8DAx
3AC500-600V +10% -10% 47-63Hz
18,5
22 no
D
122 6SE6440-2UE32-2DAx
3AC500-600V +10% -10% 47-63Hz
22
30 no
D
123 6SE6440-2UE33-0EAx
3AC500-600V +10% -10% 47-63Hz
30
37 no
E
124 6SE6440-2UE33-7EAx
3AC500-600V +10% -10% 47-63Hz
37
45 no
E
125 6SE6440-2UE34-5FAx
3AC500-600V +10% -10% 47-63Hz
45
55 no
F
126 6SE6440-2UE35-5FAx
3AC500-600V +10% -10% 47-63Hz
55
75 no
F
127 6SE6440-2UE37-5FAx
3AC500-600V +10% -10% 47-63Hz
75
90 no
F
1001 6SE6440-2UD38-8FAx
3AC400-480V +10% -10% 47-63Hz
90
110 no
FX
1002 6SE6440-2UD41-1FAx
3AC400-480V +10% -10% 47-63Hz
110
132 no
FX
1003 6SE6440-2UD41-3GAx 3AC400-480V +10% -10% 47-63Hz
132
160 no
GX
1004 6SE6440-2UD41-6GAx 3AC400-480V +10% -10% 47-63Hz
160
200 no
GX
1005 6SE6440-2UD42-0GAx 3AC400-480V +10% -10% 47-63Hz
200
250 no
GX
Notice:
Parameter r0200 = 0 indicates that no power stack has been identified.
P0201
Power stack code number
Min: 0
CStat:
C
Datatype: U16 Unit:
-
Def:
0
P-Group: INVERTER
Active: first confirm
QuickComm.: No
Max: 65535
Confirms actual power stack identified.
r0203
Act. inverter type
Min: -
Datatype: U16 Unit:
-
Def:
-
P-Group: INVERTER
Max: -
Type number of actual inverter identified.
Possible Settings:
1 MICROMASTER
420
2 MICROMASTER
440
3
MICRO- / COMBIMASTER 411
4 MICROMASTER
410
5 Reserved
6
MICROMASTER 440 PX
7 MICROMASTER
430
Level
3
Level
3