beautypg.com

Siemens 440 User Manual

Page 208

background image

Parameter Description

Issue 01/06

MICROMASTER 440 Parameter List

208

6SE6400-5BB00-0BP0

P2104[3]

BI: 2. Faults acknowledgement

Min: 0:0

CStat:

CT

Datatype: U32 Unit:

-

Def:

0:0

P-Group: COMMANDS

Active: first confirm

QuickComm.: No

Max: 4000:0

Selects second source of fault acknowledgement.

Index:

P2104[0] : 1st. Command data set (CDS)
P2104[1] : 2nd. Command data set (CDS)
P2104[2] : 3rd. Command data set (CDS)

Common Settings:

722.0 = Digital input 1 (requires P0701 to be set to 99, BICO)
722.1 = Digital input 2 (requires P0702 to be set to 99, BICO)
722.2 = Digital input 3 (requires P0703 to be set to 99, BICO)
722.3 = Digital input 4 (requires P0704 to be set to 99, BICO)
722.4 = Digital input 5 (requires P0705 to be set to 99, BICO)
722.5 = Digital input 6 (requires P0706 to be set to 99, BICO)
722.6 = Digital input 7 (via analog input 1, requires P0707 to be set to 99)
722.7 = Digital input 8 (via analog input 2, requires P0708 to be set to 99)

P2106[3] BI:

External

fault

Min: 0:0

CStat:

CT

Datatype: U32 Unit:

-

Def:

1:0

P-Group: COMMANDS

Active: first confirm

QuickComm.: No

Max: 4000:0

Selects source of external faults.

Index:

P2106[0] : 1st. Command data set (CDS)
P2106[1] : 2nd. Command data set (CDS)
P2106[2] : 3rd. Command data set (CDS)

Common Settings:

722.0 = Digital input 1 (requires P0701 to be set to 99, BICO)
722.1 = Digital input 2 (requires P0702 to be set to 99, BICO)
722.2 = Digital input 3 (requires P0703 to be set to 99, BICO)
722.3 = Digital input 4 (requires P0704 to be set to 99, BICO)
722.4 = Digital input 5 (requires P0705 to be set to 99, BICO)
722.5 = Digital input 6 (requires P0706 to be set to 99, BICO)
722.6 = Digital input 7 (via analog input 1, requires P0707 to be set to 99)
722.7 = Digital input 8 (via analog input 2, requires P0708 to be set to 99)

r2110[4] Warning

number

Min: -

Datatype: U16 Unit:

-

Def:

-

P-Group: ALARMS

Max: -

Displays warning information.

A maximum of 2 active warnings (indices 0 and 1) and 2 historical warnings (indices 2 and 3) may be
viewed.

Index:

r2110[0] : Recent Warnings --, warning 1
r2110[1] : Recent Warnings --, warning 2
r2110[2] : Recent Warnings -1, warning 3
r2110[3] : Recent Warnings -1, warning 4

Note:

-

Indices 0 and 1 are not stored.

-

The keypad will flash while a warning is active. The LEDs indicate the warning status in this case.


-

If an AOP is in use, the display will show number and text of the active warning.

P2111

Total number of warnings

Min: 0

CStat:

CT

Datatype: U16 Unit:

-

Def:

0

P-Group: ALARMS

Active: first confirm

QuickComm.: No

Max: 4

Displays number of warning (up to 4) since last reset. Set to 0 to reset the warning history.












Level

3

Level

3

Level

2

Level