Issue 01/06 parameter description – Siemens 440 User Manual
Page 217

Issue 01/06
Parameter Description
MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0
217
P2174[3]
Torque threshold M_thresh
Min: 0.00
CStat:
CUT
Datatype: Float Unit:
Nm
Def:
5.13
P-Group: ALARMS
Active: Immediately
QuickComm.: No
Max: 99999.00
Defines torque threshold for comparing actual torque.
–
+
0
1
{
0
1
SET
(Q=1) Q
RESET
(Q=0) Q
&
Entry freq. deviat
0.00 ... 20.00 [Hz]
P2163.D ( 3.00)
Hyster freq deviat
0.00 ... 10.00 [Hz]
P2164.D (3.00)
Delay_T rampUpCmpl
0 ... 10000 [ms]
P2166.D (10)
Torque threshold
0.00 ... 99999.00 [Nm]
P2174.D (5.13)
Delay time torque
0 ... 10000 [ms]
P2176.D (10)
f_act
RFG active
f_set
Ramp-up
completed
(active-high)
| M_actNoAcc |
> M_thresh
| M_act | > M_thresh
M_act | > M_thresh
M_actNoAcc | > M_thresh
Priority
1 RESET
2 SET
T 0
T 0
r2198 Bit10
r2198 Bit09
M_act
Index:
P2174[0] : 1st. Drive data set (DDS)
P2174[1] : 2nd. Drive data set (DDS)
P2174[2] : 3rd. Drive data set (DDS)
P2176[3]
Delay time for torque threshold
Min: 0
CStat:
CUT
Datatype: U16 Unit:
ms
Def:
10
P-Group: ALARMS
Active: Immediately
QuickComm.: No
Max: 10000
Delay time for comparing actual torque to threshold.
Index:
P2176[0] : 1st. Drive data set (DDS)
P2176[1] : 2nd. Drive data set (DDS)
P2176[2] : 3rd. Drive data set (DDS)
P2177[3]
Delay time for motor is blocked
Min: 0
CStat:
CUT
Datatype: U16 Unit:
ms
Def:
10
P-Group: ALARMS
Active: Immediately
QuickComm.: No
Max: 10000
Delay time for identification that motor is blocked.
Index:
P2177[0] : 1st. Drive data set (DDS)
P2177[1] : 2nd. Drive data set (DDS)
P2177[2] : 3rd. Drive data set (DDS)
P2178[3]
Delay time for motor pulled out
Min: 0
CStat:
CUT
Datatype: U16 Unit:
ms
Def:
10
P-Group: ALARMS
Active: Immediately
QuickComm.: No
Max: 10000
Delay time for identification that motor is pulled out.
Index:
P2178[0] : 1st. Drive data set (DDS)
P2178[1] : 2nd. Drive data set (DDS)
P2178[2] : 3rd. Drive data set (DDS)
Level
2
Level
2
Level
2
Level
2