Parameter Description
Issue 01/06
MICROMASTER 440 Parameter List
160
6SE6400-5BB00-0BP0
P1321[3]
Programmable V/f volt. coord. 1
Min: 0.0
CStat:
CUT
Datatype: Float Unit:
V
Def:
0.0
P-Group: CONTROL
Active: Immediately
QuickComm.: No
Max: 3000.0
See P1320 (programmable V/f freq. coord. 1).
Index:
P1321[0] : 1st. Drive data set (DDS)
P1321[1] : 2nd. Drive data set (DDS)
P1321[2] : 3rd. Drive data set (DDS)
P1322[3]
Programmable V/f freq. coord. 2
Min: 0.00
CStat:
CT
Datatype: Float Unit:
Hz
Def:
0.00
P-Group: CONTROL
Active: Immediately
QuickComm.: No
Max: 650.00
See P1320 (programmable V/f freq. coord. 1).
Index:
P1322[0] : 1st. Drive data set (DDS)
P1322[1] : 2nd. Drive data set (DDS)
P1322[2] : 3rd. Drive data set (DDS)
P1323[3]
Programmable V/f volt. coord. 2
Min: 0.0
CStat:
CUT
Datatype: Float Unit:
V
Def:
0.0
P-Group: CONTROL
Active: Immediately
QuickComm.: No
Max: 3000.0
See P1320 (programmable V/f freq. coord. 1).
Index:
P1323[0] : 1st. Drive data set (DDS)
P1323[1] : 2nd. Drive data set (DDS)
P1323[2] : 3rd. Drive data set (DDS)
P1324[3]
Programmable V/f freq. coord. 3
Min: 0.00
CStat:
CT
Datatype: Float Unit:
Hz
Def:
0.00
P-Group: CONTROL
Active: Immediately
QuickComm.: No
Max: 650.00
See P1320 (programmable V/f freq. coord. 1).
Index:
P1324[0] : 1st. Drive data set (DDS)
P1324[1] : 2nd. Drive data set (DDS)
P1324[2] : 3rd. Drive data set (DDS)
P1325[3]
Programmable V/f volt. coord. 3
Min: 0.0
CStat:
CUT
Datatype: Float Unit:
V
Def:
0.0
P-Group: CONTROL
Active: Immediately
QuickComm.: No
Max: 3000.0
See P1320 (programmable V/f freq. coord. 1).
Index:
P1325[0] : 1st. Drive data set (DDS)
P1325[1] : 2nd. Drive data set (DDS)
P1325[2] : 3rd. Drive data set (DDS)
P1330[3]
CI: Voltage setpoint
Min: 0:0
CStat:
T
Datatype: U32 Unit:
-
Def:
0:0
P-Group: CONTROL
Active: first confirm
QuickComm.: No
Max: 4000:0
BICO parameter for selecting source of voltage setpoint for independent V/f control.
Index:
P1330[0] : 1st. Command data set (CDS)
P1330[1] : 2nd. Command data set (CDS)
P1330[2] : 3rd. Command data set (CDS)
Level
3
Level
3
Level
3
Level
3
Level
3
Level
3