XG Series User's Guide

Chapter 6 Managing the Device

Verifying the Device Operations

553

5)

access_direction

Direction where a device is installed in.
front access

: The device should be installed forward.

rear access

: The device should be installed backward.

6)

power_redundancy

State of the redundant power unit.
single

: The device has no redundant power unit.

redundant

: The device has a redundant power unit.

7)

PSU1 state

State of the power unit (PSU1).

PSU2 state

Type of the power unit (PSU2).
NORMAL

: The power unit works normally.

NO_PRESENT : The power unit is not installed.
NO_POWER

: The power unit has been turned off.

FAIL

: The power unit has been abnormal.

UNKNOWN

: The power unit is invalid type.

WARNING

: The power unit has been incorrectly mounted.

8)

PSU1 type

Type of the power unit (PSU1).

PSU2 type

Type of the power unit (PSU2).
AC

: The power unit is AC.

--

: The power unit is not installed or invalid type.

9)

power_consumption

Power consumption of the device.

10)

FAN1 state

State of the fan module 1.

FAN2 state

State of the fan module 2.
NORMAL

: The fan module works normally.

FAIL

: The fan module has been abnormal.

NO_PRESENT : The fan module is not installed.
UNKNOWN

: The fan module is invalid direction.

WARNING

: The fan module has been incorrectly mounted.

11)

inspiration_state

State of environment temperature monitor.

internal_state

State of device inside temperature monitor.
NORMAL

: The temperature is normal.

WARNING

: The device changes to a high temperature state.

ALARM

: Thermal alarm occurs in the device.

12)

State of changing thermal state

warning time

: The time when a device changed in a high temperature state.

recover time

: The time when a device returned to a normal state.

13)

inspiration_temp

Environment temperature.

internal_temp

Device inside temperature.