beautypg.com

FUJITSU XG Series P3NK-4452-01ENZD User Manual

Page 549

background image

XG Series User's Guide

Chapter 6 Managing the Device

Verifying the Device Operations

549

When a SFP+ Card is installed.

1)

Current time

Present date and time.

2)

Startup time

Date and time when the system started up.

3)

restart_cause

Cause for the system startup.
The following system startup causes are displayed:
power on

: The power has been turned on.

reset

: The reset command has been issued.

reset switch

: The [RESET] switch has been pressed.

system down

: System-down has occurred.

4)

machine_state

State of the device
RUNNING

: The device is active.

5)

power0_state

State of the power unit.
NORMAL

: The power unit works normally.

NO_PRESENT : The power unit is not installed.
FAIL

: The power unit has been turned off.

UNKNOWN

: The power unit is invalid state.

6)

fan0_state

State of the fan 0.
NORMAL

: The fan works normally.

ABNORMAL

: The fan has been abnormal.

UNKNOWN

: The fan is invalid state.

7)

inspiration_state

State of environment temperature monitor.

phy_state

State of temperature monitor around PHY.

slot1_state

State of Expansion Card temperature monitor (SLOT1).

# show system status

Current-time

: Wed Dec 10 06:03:04 2008

---(1)

Startup-time

: Wed Dec 10 06:02:19 2008

---(2)

restart_cause

: reset

---(3)

machine_state

: RUNNING

---(4)

power0_state

: NORMAL

---(5)

fan0_state

: NORMAL

---(6)

inspiration_state

: NORMAL

---(7)

phy_state

: NORMAL

slot1_state

: NORMAL

inspiration_temp

: 25 C

---(8)

phy_temp

: 39 C

slot1_temp

: 39 C

Slot Information

slot1

: SJ10GSFPZ

---(9)