beautypg.com

28 linkaggregation downrelay recovery cause, Linkaggregation downrelay recovery cause, Command – FUJITSU XG Series P3NK-4452-01ENZD User Manual

Page 118

background image

XG Series User's Guide

Chapter 5 Command Reference

Port Information Settings

118

Default

It is assumed that "manual" was specified for releasing the offline state operation of the
linked port list.

5.1.1.28 linkaggregation downrelay recovery cause

Function

Set the target parameters for offline state release in the Linkdown Relay function of the
linkaggregation.

Available Model

XG0224 / XG0448 / XG2600

Syntax

linkaggregation downrelay recovery cause

Options


• Link aggregation group number

Set a link aggregation group number with a decimal number.


Specify the offline parameters targeted to offline state release of the linked port from the
following.
• downrelay

Specify when offline parameters by the Linkdown Relay function are targeted for
release.

• all

Release offline state of all parameters.

Use Mode

Configuration mode (admin class)

Explanation

Set the offline parameters lead by linkup assigned for releasing the offline state when
"auto" is specified in the "ether downrelay recovery" command.

Caution

• This command is enabled only when "auto" is set for offline state release operation

(

"ether downrelay recovery mode"

command) lead by linkup.

The definition is ignored when "manual" is specified.

• The offline state is released independent of this command definition when the

"online"

command in the linked port is executed, or during dynamic definition change
accompanied by releasing the offline state.

Default

It is assumed that "downrelay" was specified as the target parameters for offline state
release of the linked port list.

linkaggregation downrelay recovery mode manual

Range

Model

1 to 13

XG0224

1 to 26

XG0448

1 to 10

XG2600

linkaggregation downrelay recovery cause downrelay