beautypg.com

14 ether startup – FUJITSU XG Series P3NK-4452-01ENZD User Manual

Page 104

background image

XG Series User's Guide

Chapter 5 Command Reference

Port Information Settings

104

5.1.1.14 ether startup

Function

Set the offline status when it is started up.

Available Model

XG0224 / XG0448 / XG2600

Syntax

ether startup

Options


• ether port number

Set a port number to use with a decimal value.
When setting multiple port numbers, separate them with commas (,).
When setting sequential numbers, separate them with hyphens (-). (Example: "1-8")


• online

The port starts operation in the online state during device startup or during dynamic
definition reflection.

• offline

The port starts operation in the offline state during device startup or during dynamic
definition reflection. Also, wait for an offline release instruction from operator.

Use Mode

Configuration mode (admin class)

Explanation

Set the port in offline state during device startup or during reflection of dynamic
definitions.
During device startup or during change of dynamic definitions, the relationship between
the Ethernet port state and the port offline state is as follows.

Caution

If ports are offline, release them with the

"online"

command with port releasing.

Default

It is assumed that forcible offline processing to the port is not performed during device
startup or during reflection of dynamic definitions.

Ether port state during device startup or dynamic definitions change

Linkup possible

Linkup impossible

Port offline

online

Linkup or Communication
possible

Linkdown or
Communication
impossible

Communication
impossible
staying in offline state

offline

Communication
impossible
entering offline state

Communication
impossible
entering offline state

Communication
impossible
staying in offline state

ether startup online