XG Series User's Guide

Chapter 5 Command Reference

Port Information Settings

107

5.1.1.17 ether downrelay recovery mode

Function

Set offline state release operation on the Linkdown Relay function of the Ethernet port.

Available Model

XG0224 / XG0448 / XG2600

Syntax

ether downrelay recovery mode

Options


• The Ethernet port number

Set a port number to use with a decimal value.
When setting multiple port numbers, separate them with commas (,).
When setting sequential numbers, separate them with hyphens (-). (Example: "1-8")


Set offline state release operation on the linked port list.
• manual

Specify offline state release with command.

• auto

Specify offline state release with linkup.

Use Mode

Configuration mode (admin class)

Explanation

Set offline state release operation from the offline port set on the linked port list
information of the Linkdown Relay function.
Setting "manual" for the releasing operation enables the releasing operation of the linked
port by

"online"

command or dynamic definition change.

If the release setting is "auto", the linked ports offline release is possible with the linkdown
relay function setting port's linkup as well as the

"online"

command and a dynamic

definition change.
When the releasing offline operation by linkup is executed when "auto" is set, the system
log is output.

Caution

• When the Ethernet port where the Linkdown Relay function is set is in an offline state,

release the offline state with the

"online"

command, setting "auto" does not change the

state to be linked up.

• Even if the linked port is in an offline state due to something other than the Linkdown

Relay, set the parameters with

"linkaggregation downrelay recovery cause"

command

when releasing the offline state.

• When the Ethernet port type is a linkaggregation port, and the linked port list

information for the Linkdown Relay function of the linkaggregation is set, the Linkdown
Relay function of the linkaggregation becomes enable and this definition is ignored.

• Even if "auto" is set for release operation, offline state release operation will not be

executed to the ether ports still in a linkup state since some ports are already shifting to
online or offline state.

• Linkdown Relay function operates by ether port or by linkaggregation, but not by

backup port.
For this reason, when the same link operation port is set on an ether or linkaggregation
port in the same backup group, and "auto" is set for offline state release operation, the
release operation may not be executed because the operation is performed by one port
at a time.

Default

It is assumed that "manual" was specified for the linked port list offline state release
operation.

ether downrelay recovery mode manual