FUJITSU XG Series P3NK-4452-01ENZD User Manual
Page 359

XG Series User's Guide
Chapter 5 Command Reference
System Operations and Display Commands
359
3)
restart_cause
Cause for the system startup.
The following system startup causes are displayed:
power on
: The power has been turned on.
reset
: The reset command has been issued.
reset switch : The [RESET] switch has been pressed.
system down : System-down has occurred.
4)
machine_state
State of the device
RUNNING
: The device is active.
FALLBACK
: The device is into fallback state.
5)
access_direction
Direction where a device is installed in.
front access
: The device should be installed forward.
rear access
: The device should be installed backward.
6)
power_redundancy
State of the redundant power unit.
single
: The device has no redundant power unit.
redundant
: The device has a redundant power unit.
7)
PSU1 state
State of the power unit (PSU1).
PSU2 state
Type of the power unit (PSU2).
NORMAL
: The power unit works normally.
NO PRESENT
: The power unit is not installed.
NO POWER
: The power unit has been turned off.
FAIL
: The power unit has been abnormal.
UNKNOWN
: The power unit is invalid type.
WARNING
: The power unit has been incorrectly mounted.
8)
PSU1 type
Type of the power unit (PSU1).
PSU2 type
Type of the power unit (PSU2).
AC
: The power unit is AC.
--
: The power unit is not installed or invalid type.
9)
power_consumption
Power consumption of the device.
10)
FAN1 state
State of the fan module 1.
FAN2 state
State of the fan module 2.
NORMAL
: The fan module works normally.
FAIL
: The fan module has been abnormal.
NO PRESENT
: The fan module is not installed.
UNKNOWN
: The fan module is invalid direction.
WARNING
: The fan module has been incorrectly mounted.