FUJITSU XG Series P3NK-4452-01ENZD User Manual
Page 552
XG Series User's Guide
Chapter 6 Managing the Device
Verifying the Device Operations
552
slot2_temp
temperature around Expansion Card (SLOT2).
At the time of three following states, "--" is displayed.
The Expantion Card without Thermal Sensor is installed. (CX4)
The Invalid Expantion Card is installed.
The Expantion Card is not installed.
9)
Slot Information
The type of Expansion Card.
SJ10GCX4Z
: Installed Expansion Card is SJ10GCX4A. (CX4)
SJ10GSFPZ
: Installed Expansion Card is SJ10GSFPA. (SFP+)
NO_PRESENT : The Expantion Card is not installed.
UNKNOWN
: Installed Expansion Card is Invalid Card.
10)
power_consumption
Power consumption of the device.
XG2600
1)
Current time
Present date and time.
2)
Startup time
Date and time when the system started up.
3)
restart_cause
Cause for the system startup.
The following system startup causes are displayed:
power on
: The power has been turned on.
reset
: The reset command has been issued.
reset switch : The [RESET] switch has been pressed.
system down : System-down has occurred.
4)
machine_state
State of the device
RUNNING
: The device is active.
FALLBACK
: The device is into fallback state.
# show system status
Current-time
: Thu Dec 21 16:04:50 2008
---(1)
Startup-time
: Thu Dec 21 16:04:36 2008
---(2)
restart_cause
: power on
---(3)
machine_state
: RUNNING
---(4)
access_direction
: front access
---(5)
power_redundancy
: redundant
---(6)
PSU1 state
: NORMAL
---(7)
PSU2 state
: NORMAL
PSU1 type
: AC
---(8)
PSU2 type
: AC
power_consumption
: 75 W
---(9)
FAN1 state
: NORMAL
---(10)
FAN2 state
: NORMAL
inspiration_state
: NORMAL
inspiration_temp
: NORMA
---(11)
warning time
: Fri Dec 26 14:00:45 2008
---(12)
recover time
: Fri Dec 26 14:12:30 2008
internal_state
: NORMAL
inspiration_temp
: 35 C
---(13)
internal_temp
: 32 C