Figure 16 Troubleshooting GRE
Symptom
The interfaces at both ends of the tunnel are configured correctly and can ping each other, but Host A
and Host B cannot ping each other.
Solution
•
Execute the display ip routing-table command on Router A and Router C to view whether Router A
has a route over tunnel 0 to 10.2.0.0/16 and whether Router C has a route over tunnel 0 to
10.1.0.0/16.
•
If such a route does not exist, execute the ip route-static command in system view to add the route.
Take Router A as an example:
[RouterA] ip route-static 10.2.0.0 255.255.0.0 tunnel 1
IP network
IP network
Router A
Router B
Router C
Host A
Host B
10.1.1.1/16
10.2.1.1/16
Tunnel0
Tunnel0
IP network
GRE Tunnel
This manual is related to the following products:
- H3C SecPath F5000-A5 Firewall H3C SecPath F1000-A-EI H3C SecPath F1000-E-SI H3C SecPath F1000-S-AI H3C SecPath F5000-S Firewall H3C SecPath F5000-C Firewall H3C SecPath F100-C-SI H3C SecPath F1000-C-SI H3C SecPath F100-A-SI H3C SecBlade FW Cards H3C SecBlade FW Enhanced Cards H3C SecPath U200-A U200-M U200-S H3C SecPath U200-CA U200-CM U200-CS