109
Description: Tunnel2 Interface
The Maximum Transmit Unit is 64000
Internet Address is 30.1.2.2/24 Primary
Encapsulation is TUNNEL, service-loopback-group ID not set
Tunnel source 2002::0002:0001, destination 2002::0001:0001
Tunnel protocol/transport IP/IPv6
Output queue : (Urgent queuing : Size/Length/Discards) 0/100/0
Output queue : (Protocol queuing : Size/Length/Discards) 0/500/0
Output queue : (FIFO queuing : Size/Length/Discards) 0/75/0
Last 300 seconds input: 1 bytes/sec, 0 packets/sec
Last 300 seconds output: 1 bytes/sec, 0 packets/sec
167 packets input, 10688 bytes
0 input error
170 packets output, 10880 bytes
0 output error
# Ping the IPv4 address of the peer interface GigabitEthernet 0/1 from Router A.
[RouterA] ping 30.1.3.1
PING 30.1.3.1: 56 data bytes, press CTRL_C to break
Reply from 30.1.3.1: bytes=56 Sequence=1 ttl=255 time=46 ms
Reply from 30.1.3.1: bytes=56 Sequence=2 ttl=255 time=15 ms
Reply from 30.1.3.1: bytes=56 Sequence=3 ttl=255 time=16 ms
Reply from 30.1.3.1: bytes=56 Sequence=4 ttl=255 time=15 ms
Reply from 30.1.3.1: bytes=56 Sequence=5 ttl=255 time=16 ms
--- 30.1.3.1 ping statistics ---
5 packet(s) transmitted
5 packet(s) received
0.00% packet loss
round-trip min/avg/max = 15/21/46 ms
Configuring a DS-Lite tunnel
The following section describes the DS-Lite tunnel configuration on the CPE and on the AFTR.
Configuration prerequisites
Configure IPv6 addresses for interfaces (such as the VLAN interface, GigabitEthernet interface, and
loopback interface). One of the interfaces will be used as the source interface of the tunnel.
Configuring the CPE of a tunnel
You can configure the CPE of a DS-Lite tunnel or IPv4 over IPv6 manual tunnel.
•
If you configure a DS-Lite tunnel on the CPE, the CPE automatically obtains the IPv6 address of the
AFTR through DHCPv6 and uses the address as the destination address of the tunnel.
•
If you configure an IPv4 over IPv6 manual tunnel on the CPE, you must manually specify the address
of the AFTR as the destination address of the tunnel.
- H3C SecPath F5000-A5 Firewall H3C SecPath F1000-A-EI H3C SecPath F1000-E-SI H3C SecPath F1000-S-AI H3C SecPath F5000-S Firewall H3C SecPath F5000-C Firewall H3C SecPath F100-C-SI H3C SecPath F1000-C-SI H3C SecPath F100-A-SI H3C SecBlade FW Cards H3C SecBlade FW Enhanced Cards H3C SecPath U200-A U200-M U200-S H3C SecPath U200-CA U200-CM U200-CS