DeviceNet™ Information Appendix B

143

Get/Set

Jam Trip Level

UINT

0…600 %FLA

250

144

Get/Set

Jam Warn Level

UINT

0…600 %FLA

150

145

Get/Set

UL Inhibit Time

USINT

0…250 seconds

10

146

Get/Set

UL Trip Delay

USINT

0.1…25.0 seconds

5.0

147

Get/Set

UL Trip Level

USINT

10…100 %FLA ➊

50

148

Get/Set

UL Warn Level

USINT

10…100 %FLA ➊

70

149

Get/Set

CI Inhibit Time

USINT

0…250 seconds

10

150

Get/Set

CI Trip Delay

USINT

0.1…25.0 seconds

5.0

151

Get/Set

CI Trip Level

USINT

10…100 %FLA

35

152

Get/Set

CI Warn Level

USINT

10…100 %FLA

20

153 ➍

Get/Set

GF Trip Inhibit

USINT

0 = Enabled
1 = Disabled

0

154 ➍

Get/Set

2-Spd Net Enable

USINT

0 = Disabled
1 = Enabled

0

155 ➍

Get/Set

2-Spd FLA Set

UINT

This attribute exists
only for current ranetgs
that report 1 or 2
decimal places
resolution

Current
Range
Dependent

156 ➍

Get/Set

2-Spd FLA Set
Times 10

UINT

This attribute exists
only for current ranetgs
that report 2 decimal
places resolution

Current
Range
Dependent

157 ➍

Get/Set

2-Spd FLA Set
Div 10

UINT

This attribute exists
only for current ranetgs
that report 0 decimal
place resolution

Current
Range
Dependent

178

Get/Set

CT Ratio

USINT

50:5…5000:5

50:5

180

Get/Set

GF Warning Delay

USINT

0.1 s

181

Get/Set

GF Ssensing
Range

UINT

0 = 20…100 mA
1 = 100…500 mA
2 = 0.2…1.0 mA
3 = 1.0…5.0 mA

The following attributes are used to support multiple current ranges.

190➋
224➌

Get/Set

FLC Set Times 10

UINT

This attribute exists
only for current ranges
that report 2 decimal
place resolution

Current
Range
Dependent

191➋
225➌

Get/Set

FLC Set Div 10

UINT

This attribute exists
only for current ranges
that report 0 decimal
place resolution

Current
Range
Dependent

192➋
226➌

Get

Avg Current
Times 10

UINT

This attribute exists
only for current ranges
that report 2 decimal
place resolution

Current
Range
Dependent

193➋
227➌

Get

L1 Current Times
10

UINT

This attribute exists
only for current ranges
that report 2 decimal
place resolution

Current
Range
Dependent

194➋
228➌

Get

L2 Current Times
10

UINT

This attribute exists
only for current ranges
that report 2 decimal
place resolution

Current
Range
Dependent

Table 120 - Overload Object Instance Attributes

Attribute
ID

Access
Rule

Name

Data
Type

Value

Default