3 upgrading firmware on an infiniband adapter, Upgrading firmware on an infiniband adapter -18, Section 8.2.2 – HP StorageWorks Scalable File Share User Manual
Page 216: 2 upgrading firmware on, Sfs20 arrays

Replacing, adding, and removing hardware, and upgrading firmware
8–18
8.2.2 Upgrading firmware on
Smart Array 6404 adapters and
SFS20 arrays
The HP StorageWorks Scalable File Share Release Notes provide details of the correct firmware version for
the SFS20 array as well as details of where you can obtain firmware source files.
This section provides instructions for upgrading the firmware on all SFS20 arrays and all Smart Array 6404
adapters in your HP SFS system.
•
If you want to upgrade only the firmware on the SFS20 arrays, skip Steps 4, 5, and 12.
•
If you want to upgrade only the firmware on the Smart Array 6404 adapters, skip Steps 6, 7, 8, and
13.
To upgrade the firmware on all SFS20 arrays and all Smart Array 6404 adapters in your HP SFS system,
perform the following steps:
1.
Obtain the appropriate firmware executable (
.scexe
) files (refer to the HP StorageWorks Scalable
File Share Release Notes for details of the correct firmware version as well as details of where you
can obtain firmware executable files).
2.
Stop all file systems.
3.
Stop the clustering software on all servers in the HP SFS system, by entering the following command
on each server:
# service cluster stop
4.
Copy the Smart Array 6404 adapter firmware executable file to the
/var
directory on each server.
5.
Run the executable file on each server to upgrade the adapter firmware.
6.
Shut down one server in each server pair; for example, shut down all even-numbered servers.
7.
Copy the SFS20 array firmware executable file to the
/var
directory on each of the servers that are
still running (for example, all odd-numbered servers).
8.
Run the executable file on each of the servers that are running.
9.
Shut down the servers where you have run the executable file.
10.
Power cycle all of the SFS20s arrays in the system.
11.
Boot all of the servers in the system, as described in Section 3.1.
12.
When all of the servers in the system have booted, start the SFS CLI and enter the
show server
server_name
command for each server to verify that the firmware version on the adapters is
correct.
13.
Enter the
show array array_number
command for each array to verify that the firmware has
been upgraded to the correct version.
8.2.3 Upgrading firmware on an InfiniBand adapter
The HP StorageWorks Scalable File Share Release Notes provide details of the correct firmware version for
InfiniBand adapters.
Firmware files for Voltaire PCI-X HCA adapters are included in the HP SFS server software and are
automatically placed in the appropriate directory when the HP SFS system software is installed. The
firmware on the adapters is not automatically upgraded when the HP SFS system software is installed.