Verifying the system

6–9

normally, and that the problem is related to array 3. Examine the controller and switch connections,

and correct any faults before proceeding to the next step.

7.

When you have corrected any faults in the controller and switch connections, turn on the power to all

Fibre Channel switches.

8.

Reboot all servers, as described in Steps 2 through 5 above.

9.

Use the

show lun

command as described in Step 6 above to verify that each LUN is visible to two

servers in a server pair.

10.

Turn off the power to (or remove the power cable from) the Fibre Channel switches on the second

Fibre Channel fabric connection.

11.

After 30 seconds, enter the

show server

command and verify that all servers are still running; that

is, the output in the

State

field is set to

running

for all servers.

12.

Use the

show lun

command as described in Step 6 above to verify that each LUN is visible to two

servers in a server pair.

13.

Turn on the power to all Fibre Channel switches.

6.1.4 Confirming the status of SFS20 hardware using the hpacucli utility

You can use the

hpacucli

utility to view information about the SFS20 arrays attached to a server, and

information about the Smart Array 6404 HBA controllers on the server. This section describes how to use

this utility, and describes the information that you should examine.

Log into one of the servers to which the array is attached, and start the

hpacucli

utility by entering the

following command:

# hpacucli

HP Array Configuration Utility CLI 7.50.18.0
Detecting Controllers...Done.
Type "help" for a list of supported commands.
Type "exit" to close the console.
=>

To view information about the SFS20 arrays attached to a server, use the information provided in the

following sections:

Identifying SFS20 array serial numbers (Section 6.1.4.1)

Reviewing SFS20 array information (Section 6.1.4.2)

To view information about the Smart Array 6404 HBA controllers on a server, use the information provided

in the following sections:

Identifying Smart Array 6404 HBA controller serial numbers (Section 6.1.4.3)

Reviewing Smart Array 6404 HBA controller information (Section 6.1.4.4)

6.1.4.1

Identifying SFS20 array serial numbers

To identify the serial numbers of the SFS20 arrays attached to a server using the

hpacucli

utility, enter the

following command:

=> controller all show

MSA20 at 01 (sn: P6C8CX7MQPS7UG)
MSA20 at 02 (sn: P6C8CX7MQPS7X6)
Smart Array 6i in Slot 0 ()
Smart Array 6400 EM in Slot 3b(sn: P577C0G9SQF0K8)
Smart Array 6400 in Slot 3 (sn: P57820H9SQE1Y9)