2 creating mirrored ost luns on sfs20 arrays, Creating mirrored ost luns on sfs20 arrays -20 – HP StorageWorks Scalable File Share User Manual

Page 104

background image

Creating and modifying file systems

5–20

Here are the available LUNs which you can assign to OSTs:

LUN Array Controller Role Size (GB) Visible to Preferred
--- ----- ---------- ---- --------- --------- ---------
8 3 scsi-1/1 ost 1050 south[3-4] south3
13 5 scsi-2/1 ost 1050 south[3-4] south3
11 4 scsi-1/2 ost 1050 south[3-4] south4
15 6 scsi-2/2 ost 1050 south[3-4] south4
17 7 scsi-1/1 ost 1050 south[5-6] south5
21 9 scsi-2/1 ost 1050 south[5-6] south5
19 8 scsi-1/2 ost 1050 south[5-6] south6
23 10 scsi-2/2 ost 1050 south[5-6] south6

Please enter the LUN you wish to use [8]: 8
Please enter the preferred server for this OST LUN [south3]: south3

Similarly, if a second Smart Array 6404 adapter is present, the notation continues as

scsi-3/1

,

scsi-

3/2

,

scsi-4/1

and

scsi-4/2

.

Selecting the LUNs in the order in which they are listed results in adjacent OST services that are served firstly

by the same Smart Array 6404 adapter, and secondly by the same server. For a typical configuration where

there are two Smart Array 6404 adapters and four SFS20 arrays for each Object Storage Server (a total

of eight SFS20 arrays for each Object Storage Server pair), and assuming that there is one large LUN on

each array (the recommended configuration), the first four OST services will be served from the first server

in the server pair and the second four OST services from the second server, and so on for further server pairs.

In configurations where the speed of the interconnect does not exceed the capabilities of the storage

configured (for example, if a Gigabit Ethernet interconnect is used and there are two or more SFS20 arrays

per server), consider ordering the OST services in a way that supports the possibility of increasing

bandwidth by adding Object Storage Servers. This allows you to achieve better performance for jobs that

do not stripe across every available OST. For example, you could create an OST sequence where the

adjacent OST services are configured on arrays connected to port A1 of server 1, port A2 of server 2, port

A1 of server 3 and so on, across all servers; followed by arrays connected to port B1 of server 1, port B2

of server 2, port B1 of server 3, and so on.

Where the interconnect performance exceeds the storage bandwidth, using the default striping leads to

more understandable performance. Note too that if you add, for example, a pair of Object Storage Servers

to the system, and add the associated OST services to a file system, the OST services are always added at

the end of the logical list of OST services in the file system. This means that if you create a striping pattern

following the order in which the LUNs are listed by the

create filesystem

command, the striping will

be consistent with the added storage.

HP recommends that you always prefer the storage configured on SFS20 arrays connected to ports A1 and

A2 on a Smart Array 6404 adapter to different servers, and similarly for ports B1 and B2.

5.2.2.2

Creating mirrored OST LUNs on SFS20 arrays

A Smart Array 6404 adapter has four ports: A1, A2, B1, and B2. Each SFS20 array is connected to the

same port of the Smart Array 6404 adapters on each of the two servers in a server pair.

In the output from the SFS CLI commands, port A1 is referred to as

scsi-1/1

and port A2 as

scsi-1/2

;

port B1 is referred to as

scsi-2/1

and port B2 as

scsi-2/2

. Similarly, if a second Smart Array 6404

adapter is present on the server, the notation continues as

scsi-3/1

,

scsi-3/2

,

scsi-4/1

and

scsi-4/2

.

Where two Smart Array 6404 adapters are present on each server, HP recommends that each of the

component LUNs in a mirrored OST LUN is served through a different adapter. This provides optimal

resilience for the mirrored LUN. To achieve this, make sure that two arrays do not have the same or

numerically neighboring HBA/port numbers (as shown by the

sfsmgr show array

command).

When there is only one Smart Array 6404 adapter on a server, pair a LUN connected to the

scsi-1/1

port with a LUN connected to the

scsi-2/1

port when you are creating a mirrored OST LUN.