HP StorageWorks Scalable File Share User Manual
Page 105

Creating a file System — SFS20 storage
5–21
In the following example, array1 and array 2 are connected to different Smart Array 6404 adapters on the
servers. In this example, when a mirrored OST LUN is being created, the LUN connected to the
scsi-1/1
port should be paired with the LUN connected to the
scsi-3/1
port.
sfs> show array 1
Array (WWID): P92CB0BMQS00H3
Name: -
Array Number: 1
Type: MSA20
Preferred Server: south1
Firmware: 1.92
Total Disks: 12
Free Disks: 0
Disks Per Group: 11
Raid Type: ADG
Spare Disk Count: 1
Cache Status: OK
Battery Status: OK
Connected to HBA/Port Status
-------------- ---------- ----------
south1 scsi-1/1 online
south2 scsi-1/1 online
Bay/Disk Status Bay/Disk Status Bay/Disk Status Bay/Disk Status
----------------- ----------------- ----------------- -----------------
1: ok 4: ok 7: ok 10:ok
2: ok 5: ok 8: ok 11:ok
3: ok 6: ok 9: ok 12:ok
LUN (WWID) Logical Drive
---- ----------------------------------- ----------
1 a44a6293-61090013 ok
2 a44a629c-0d770014 ok
3 a44a6281-b9860015 ok
4 a44a6285-ea4f0016 ok
5 a44a6289-b5640017 ok
6 a44a628e-c4f90018 ok
sfs> show array 2
Array (WWID): P92CB0BMQS00E3
Name: -
Array Number: 2
Type: MSA20
Preferred Server: south1
Firmware: 1.92
Total Disks: 12
Free Disks: 0
Disks Per Group: 11
Raid Type: ADG
Spare Disk Count: 1
Cache Status: OK
Battery Status: OK
Connected to HBA/Port Status
-------------- ---------- ----------
south1 scsi-3/1 online
south2 scsi-3/1 online
Bay/Disk Status Bay/Disk Status Bay/Disk Status Bay/Disk Status
----------------- ----------------- ----------------- -----------------
1: ok 4: ok 7: ok 10:ok
2: ok 5: ok 8: ok 11:ok
3: ok 6: ok 9: ok 12:ok