Verifying the system

6–7

c.

Look at the server and confirm that the power has been turned off. Only one server in the system

should be turned off at this point.

d.

Turn on the power to the server, as follows:

sfs> boot server south2

e.

Use the

show server

command to verify that the power to the server has been turned on, as

follows:

sfs> show server south2

Name: south2
Primary Role: mds
Backup Server: south1
.

.

.

Power: on
.

.

.

Repeat these steps for each server except the administration server.

3.

When you have confirmed that the power management is working correctly for the MDS server and

all of the Object Storage Servers, verify that the power management is working correctly for the

administration server by performing the following steps, where

south1

is the administration server:

a.

Log in to the MDS server.

b.

Turn off the power to the administration server, as follows:

sfs> shutdown server south1 wait=0

c.

Use the

show server

command to verify that the power to the administration server has been

turned off, as follows:

sfs> show server south1

Name: south1
Primary Role: adm
Backup Server: south2
.

.

.

Power: off
.

.

.

d.

Look at the server and confirm that the power has been turned off. Only one server in the system

should be turned off at this point.

e.

Turn on the power to the administration server, as follows:

sfs> boot server south1

f.

Use the

show server

command to verify that the power to the administration server has been

turned on, as follows:

sfs> show server south1

Name: south1
Primary Role: mds
Backup Server: south2
.

.

.

Power: on
.

.

.