Verifying, diagnosing, and maintaining the system

6–4

Table 6-2 lists the components, the component tests, and the level of each test.

severity

Specifies the severity levels that are to be reported from the tests. Valid values are

1

,

2

,

3

,

4

.

You can use this option to control the report generation and limit the output from

the tests. You can specify one severity level, a comma-separated list of levels, and/

or a range of levels; for example,

1,3-4

.

For example, specifying severity=2 limits the reporting to warnings only.
The default is

severity=1-3

.

report

Specifies where the output from the tests is to be directed.
You can use this option to redirect the report to a file.
The default is

report=stdout

.

Table 6-2

Components, tests, and levels for

syscheck

command

Component

Test

Level

firmware

Check the firmware version of the BIOS on each server.

1

Check the firmware version of the iLO on each server.

1

Check the firmware version of the 6404 adapter on each

server.

1

Check the firmware version of each SFS20 array.

1

Check the firmware version of InfiniBand HCA adapters.

2

ilo

Ping server iLO.

1

interconnect

Check that each server has an Elan Network ID set in the

database (Quadrics interconnect only).

2

Check that each server is in the Elan nodeset (Quadrics

interconnect only).

2

Check that each server has a Myrinet Network ID set in the

database (Myrinet interconnect only).

2

Check the state of each interconnect link on the system.

2

network

Ping servers on each network.

1

Check that dual Gigabit Ethernet interfaces are correctly

configured.
Also check that the IP address of each interface is unique.

1

Check that the group server(s), if configured, are responding.
Check the performance of the management network adapters

(should be at least 100Mb/sec).

2

Check the performance of the Gigabit Ethernet network

adapters (should be 1000Mb/sec).

2

power

Check monitored power state of server.

1

Check power state of server.

2

server

Check run state of server.

1

Check configuration state of server.

1

Check fan, power, temperature, DIMM and Integrated

Management Log status of server.

1

Table 6-1

Arguments for the

syscheck

command

Argument

Description