HP StorageWorks Scalable File Share User Manual
Page 134

Verifying, diagnosing, and maintaining the system
6–4
Table 6-2 lists the components, the component tests, and the level of each test.
severity
Specifies the severity levels that are to be reported from the tests. Valid values are
1
,
2
,
3
,
4
.
You can use this option to control the report generation and limit the output from
the tests. You can specify one severity level, a comma-separated list of levels, and/
or a range of levels; for example,
1,3-4
.
For example, specifying severity=2 limits the reporting to warnings only.
The default is
severity=1-3
.
report
Specifies where the output from the tests is to be directed.
You can use this option to redirect the report to a file.
The default is
report=stdout
.
Table 6-2
Components, tests, and levels for
syscheck
command
Component
Test
Level
firmware
Check the firmware version of the BIOS on each server.
1
Check the firmware version of the iLO on each server.
1
Check the firmware version of the 6404 adapter on each
server.
1
Check the firmware version of each SFS20 array.
1
Check the firmware version of InfiniBand HCA adapters.
2
ilo
Ping server iLO.
1
interconnect
Check that each server has an Elan Network ID set in the
database (Quadrics interconnect only).
2
Check that each server is in the Elan nodeset (Quadrics
interconnect only).
2
Check that each server has a Myrinet Network ID set in the
database (Myrinet interconnect only).
2
Check the state of each interconnect link on the system.
2
network
Ping servers on each network.
1
Check that dual Gigabit Ethernet interfaces are correctly
configured.
Also check that the IP address of each interface is unique.
1
Check that the group server(s), if configured, are responding.
Check the performance of the management network adapters
(should be at least 100Mb/sec).
2
Check the performance of the Gigabit Ethernet network
adapters (should be 1000Mb/sec).
2
power
Check monitored power state of server.
1
Check power state of server.
2
server
Check run state of server.
1
Check configuration state of server.
1
Check fan, power, temperature, DIMM and Integrated
Management Log status of server.
1
Table 6-1
Arguments for the
syscheck
command
Argument
Description