HP StorageWorks Scalable File Share User Manual
Page 135

Verifying the system
6–5
The following is an example of the
syscheck
command when it is run with no options specified:
sfs> syscheck
..................
----------------------------------- syscheck -----------------------------------
Run on Tue Sep 12 10:20:06 IST 2006 SFS V2.2-0 (build w0H12hp)
Kernel: Linux 2.6.9-34.0.2.EL.w0H12hpsmp #1 SMP Fri Sep 1 02:47:27 IST 2006
System Serial Number: 8326LDN12422
System Type: ProLiant DL380 G3
Number of CPUs: 2
CPU Type: Intel(R) Xeon(TM) CPU 2.80GHz
Enabled Components: system ilo power server storage network interconnect firmware
Disabled Components: none
Test Level: [1-4]
Report Severity: [1-3]
----------------------------- Critical Conditions ------------------------------
storage
-------
south1 RAID LUN 26 state is offline. State will not
be updated until service mds9 is started
storage
Check that adm LUN exists and is visible to administration and
MDS servers.
1
Check that there is a service LUN for each server pair.
1
Check that each LUN is presented to two servers.
1
Check that MDS and OST LUNs are balanced between the A
and B controllers (EVA storage only).
1
Check the RAID state of each LUN.
1
Check that RAID LUN components are balanced between the A
and B controllers (EVA storage only).
1
Check the state of each LUN in the system (SFS20 arrays only). 1
Check that SFS20 arrays are dual-connected (if using shared
storage).
1
Check status of SFS20 array.
1
Check the status of the physical disks on the SFS20 array.
1
Check that SFS20 array is cabled correctly.
1
Check that each LUN on is visible on the appropriate number
of paths (EVA storage only).
1
Check that each LUN is using the preferred controller or
preferred path (EVA storage only).
1
Check that the percentage of storage used on each OST
services is less than the value of the
ost_warning_size
and
ost_critical_size
attributes.
1
system
Check that the SFS database exists.
1
Check that none of the email alerts are using the
root
user
email address.
1
Check that
Hyper-Threading
is disabled in the BIOS.
2
Table 6-2
Components, tests, and levels for
syscheck
command
Component
Test
Level