beautypg.com

Section 6.1.4.4 – HP StorageWorks Scalable File Share User Manual

Page 144

background image

Verifying, diagnosing, and maintaining the system

6–14

This example shows that there are errors in the disk’s log. Such errors do not necessarily mean that

the disk has failed or is about to fail; however, HP recommends that you periodically review the status

of any disk that is logging errors.

Repeat these steps for each SFS20 array attached to the server.

6.1.4.3

Identifying Smart Array 6404 HBA controller serial numbers

To identify the serial numbers of the Smart Array 6404 HBA controllers on a server using the

hpacucli

tool, enter the following command:

=> controller all show

MSA20 at 01 (sn: P6C8CX7MQPS7UG)
MSA20 at 02 (sn: P6C8CX7MQPS7X6)
Smart Array 6i in Slot 0 ()
Smart Array 6400 EM in Slot 3b(sn: P577C0G9SQF0K8)
Smart Array 6400 in Slot 3 (sn: P57820H9SQE1Y9)

Take note of the Smart Array 6404 HBA controller serial numbers, and proceed to Section 6.1.4.2 to view

the information on the Smart Array 6404 HBA controllers.

6.1.4.4

Reviewing Smart Array 6404 HBA controller information

To review Smart Array 6404 HBA controller information using the

hpacucli

tool, perform the following

steps:

1.

Set the Smart Array 6404 HBA controller serial number (as identified in Section 6.1.4.3) as the target

for the

hpacucli

tool, as shown in the following example:

=> set target controller sn=P577C0G9SQF0K8

controller serialnumber=P577C0G9SQF0K8
=>

2.

View the information on the Smart Array 6404 HBA controller by entering the

show

command, as

shown in the following example:

=> show

Controller Smart Array 6400 in Slot 3b
Bus Interface: pci
slot: 3b
serialnumber: P577C0G9SQF0K8
Cache serialnumber: P577A0C9SQE1T8
RAID ADG status: True
RAID ADG Enabler Status: OK
Controller Status: OK
Hardware Revision: Rev B
Firmware Version: 2.62
Rebuild Priority: Low
Expand Priority: Low
Surface Scan Delay: 0 sec
Cache Board Present: True
Cache Status: NotConfigured
Accelerator Ratio: 50/50 (read/write)
Read Cache Size: 0 MB
Write Cache Size: 0 MB
Total Cache Size: 128 MB
Battery Backed Cache Size: 128 MB
Non Battery Backed Cache Size: 0 MB
Battery Pack Count: 2
Battery Status: OK
=>

Review the output from the

show

command, as follows:

The

Controller Status

field should be set to

OK

.

The

Cache Status

field should be set to

NotConfigured

.