8.1.6 Replacing a Storage Host Bus Adapter on an EVA4000 array (HP Part
Number FCA2214 DC)
Configuration impact
Changes the WWID of the ports.
Process
1.
Update the presentation of virtual disks on each EVA. Refer to Chapter 5 of the HP StorageWorks
Scalable File Share System Installation and Upgrade Guide for information on presenting virtual
disks.
2.
Reboot the server.
8.1.7 Replacing a Fibre Channel cable (from server to Fibre Channel switch)
Configuration impact
None.
Process
Reboot the server.
8.1.8 Replacing a Fibre Channel switch
Configuration impact
None.
Process
Reboot the servers attached to the switch, but stagger the rebooting so that services are not lost, as follows:
1.
Reboot one server in each server pair attached to the switch.
2.
When the first server in each server pair has rebooted, reboot the second server in each server pair
attached to the switch.
8.1.9 Replacing an EVA4000 controller
Configuration impact
None.
Process
Reboot the servers that use the EVA4000 array.
When you replace a controller on an array, it may happen that the LUNs on the array are not correctly
presented to the controllers. You can check the LUN presentation using the
/usr/opt/hpls/diags/
bin/controller_check.bash
command, and if necessary, reconfigure the LUN presentations. See
Section 9.29 for information on troubleshooting LUN presentation.