Zone-1066, Zone-3001, Zone-3002 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 999
Fabric OS Message Reference
977
53-1003140-01
ZONE-1066
5
ZONE-1066
Message
Zoning operation failed to complete on the local switch - code
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates an IPC error occurred between Name Server and Zone Server.
Recommended
Action
The switch is in an inconsistent state and can be corrected only by a reboot or power cycle.
Upon reboot, if switch is unable to join the fabric due to a zone conflict, issue cfgClear command.
If there is an enabled-configuration, commit cfgClear operation by issuing cfgDisable.
If there is no enabled-configuration, commit cfgClear operation by issuing cfgSave.
ZONE-3001
Message
Event: member list>\" added to Message Type AUDIT Class ZONE Severity INFO Probable Cause Indicates that a new zone object member or members have been added to the specified zone object set. The zone object type variable can be an alias, zone member, zone, or zone configuration. The string "..." Recommended Action Verify that the event was planned. If the event was planned, no action is required. If the event was not ZONE-3002 Message Event: set name>\" created with Message Type AUDIT Class ZONE Severity INFO Probable Cause Indicates that a new zone object set was created and the specified zone object member or members The zone object type variable can be an alias, zone member, zone, or zone configuration. The string "..."
appears at the end of the zone object member list variable if the list was truncated in the message.
planned, take appropriate action as defined by your enterprise security policy.
were added to the zone object set.
appears at the end of the zone object member list variable if the list was truncated in the message.