Sulb-1050, Sulb-1051, Sulb-1052 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 928
906
Fabric OS Message Reference
53-1003140-01
SULB-1050
5
SULB-1050
Message
Firmwaredownload command continues.
Message Type
AUDIT | LOG
Class
FIRMWARE
Severity
INFO
Probable Cause
Indicates that the firmwareDownload command is running on the standby control processor (CP) of the
dual-CP system. This process should take approximately 17 minutes. The process is set to time out after
30 minutes.
Recommended
Action
Do not fail over or power down the system during firmware upgrade. Allow the firmwareDownload
command to continue without disruption. No action is required.
Run the firmwareDownloadStatus command for more information.
SULB-1051
Message
Detected hot-plug of Standby CP. Firmware from Active CP will automatically be
synchronized to Standby CP.
Message Type
AUDIT | LOG
Class
FIRMWARE
Severity
INFO
Probable Cause
Indicates that auto firmware synchronization has started because the standby control processor (CP) is
hot-plugged.
Recommended
Action
No action is required. Firmware download has started on the standby CP.
SULB-1052
Message
Firmwaresync has failed.
Message Type
AUDIT | LOG
Class
FIRMWARE
Severity
ERROR
Probable Cause
Indicated that auto firmware synchronization has failed.
Recommended
Action
Execute the firmwareDownloadStatus and firmwareShow commands to view firmware status.
Execute the haShow command to view the HA state.