Swch-1025, Swch-1026, Swch-1027 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 938

916
Fabric OS Message Reference
53-1003140-01
SWCH-1025
5
SWCH-1025
Message
This Logical Switch has ports other than 16 Gbps-capable FC ports. Edge Hold Time
for these ports is unchanged and is
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the edge hold time for the non 16 Gbps-capable FC ports is not the same as 16
Gbps-capable FC ports in the logical switch. The non 16 Gbps-capable FC ports use the edge hold time
configured on the default switch.
Recommended
Action
To know the edge hold time configured for non 16 Gbps-capable FC ports, go to the default switch and
execute the configShow command.
SWCH-1026
Message
HA state out of sync: Standby CP (ver =
auto csctl_mode (Active CP version =
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the standby control processor (CP) does not support auto class-specific control (CS_CTL)
mode.
Recommended
Action
Upgrade the standby CP firmware version to same level as active CP.
SWCH-1027
Message
HA state out of sync: Standby CP (ver =
NPIV Base device Logout functionality. (active ver =
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the standby control processor (CP) does not support N_Port ID Virtualization (NPIV) base
device logout functionality, but the switch has some ports with base device configured.
Recommended
Action
Load a firmware version on standby CP that supports NPIV Base device Logout functionality using the
firmwareDownload command, or change the 'base logout' feature with the portCfgNPIVPort
command.