Ham-1009, Ham-1010, Ham-1011 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 609
Fabric OS Message Reference
587
53-1003140-01
HAM-1009
5
HAM-1009
Message
Need to MANUALLY REBOOT the system for recovery - auto-reboot is disabled.
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates that the recovery by auto-restart is disabled, therefore the switch needs to be manually
restarted for recovery. This message is displayed if the event logged in HAM-1007 has occurred and
auto-reboot is disabled.
Recommended
Action
Execute the reboot command to restart the switch manually.
HAM-1010
Message
Maunually trigger haReboot/reboot for recovery from OOM when appropriate.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that out of memory (OOM) condition has been detected when the switch was not ready for
warm recovery.
Recommended
Action
Manually trigger the switch restart for cold recovery, if needed; or wait until switch is ready for warm
recovery and execute the haReboot or haFailover command.
HAM-1011
Message
haReboot is automatically triggered for warm recovery from OOM.
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates that out of memory (OOM) condition has been detected when switch was ready for warm
recovery. The haReboot is automatically triggered.
Recommended
Action
No action is required. The haReboot is automatically triggered to recover from the OOM condition.