Fw-1429, Fw-1430, Fw-1431 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 584
562
Fabric OS Message Reference
53-1003140-01
FW-1429
5
FW-1429
Message
Switch status change contributing factor: Power supplies are not redundant.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the switch is not in a healthy state. This occurred because the power supplies are not in the
correct slots for redundancy.
Recommended
Action
Rearrange the power supplies so that one is in an odd slot and another in an even slot to make them
redundant.
FW-1430
Message
Switch status change contributing factor
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the switch is not in a healthy state. This occurred because the number of faulty
temperature sensors is greater than or equal to the policy set by the switchStatusPolicySet command.
A temperature sensor is faulty when the sensor value is not in the acceptable range or is faulty.
Recommended
Action
Replace the field-replaceable unit (FRU) with the faulty temperature sensor.
FW-1431
Message
Switch status change contributing factor Fan:
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the switch is not in a healthy state. This occurred because the number of faulty fans is
greater than or equal to the policy set by the switchStatusPolicySet command. A fan is faulty when the
value is not in the acceptable range or is faulty.
Recommended
Action
Replace the faulty or deteriorating fan field-replaceable units (FRUs).