Sulb-1007, Sulb-1008, Sulb-1009 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 913
![background image](/manuals/361689/913/background.png)
Fabric OS Message Reference
891
53-1003140-01
SULB-1007
5
SULB-1007
Message
Standby CP reboots.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the standby control processor (CP) is rebooting with new firmware.
Recommended
Action
No action is required. The firmwareDownload command is progressing as expected.
Run the firmwareDownloadStatus command for more information.
SULB-1008
Message
Standby CP booted successfully with new firmware.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the standby control processor (CP) has rebooted successfully.
Recommended
Action
No action is required. The firmwareDownload command is progressing as expected.
Run the firmwareDownloadStatus command for more information.
SULB-1009
Message
Firmwaredownload command failed. Status: 0x
Message Type
AUDIT | LOG
Class
FIRMWARE
Severity
INFO
Probable Cause
Indicates that the firmwareDownload command failed. The additional status code and error code values
provide debugging information.
The following table lists firmwareDownload status messages and status codes. Some of them will
not be displayed in this RASLog message and are listed for completeness.
TABLE 7
Status messages and status codes
Status message
Status code
"Firmware download sanity check failed."
0x30
"Sanity check failed because system is non-redundant."
0x31
"Sanity check failed because firmware download is already in progress."
0x32
"Sanity check failed because Fabric OS is disabled on active CP."
0x33