beautypg.com

Ssmd messages, Ssmd-1001, Ssmd-1002 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 896: Ssmd-1003

background image

874

Fabric OS Message Reference

53-1003140-01

SSMD-1001

5

SSMD Messages

SSMD-1001

Message

Failed to allocate memory: ().

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified function has failed to allocate memory.

Recommended

Action

Check the memory usage on the switch using the memShow command.

Restart or power cycle the switch.

SSMD-1002

Message

Failed to initialize rc = .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the initialization of a module within System Services Manager (SSM) has failed.

Recommended

Action

Download a new firmware using the firmwareDownload command.

SSMD-1003

Message

Failed to lock semaphore mutex: ().

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified function has failed to lock the mutex (semaphore).

Recommended

Action

Restart or power cycle the switch.