TRCE-1007

5

TRCE-1007

Message

Notification of this MM has failed. Parameters temporarily out of sync with other

MM.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the active control processor (CP) is unable to alert the standby CP of a change in trace
status. This message is only applicable to bladed switches.

Recommended

Action

This message is often transitory. Wait a few minutes and try the command again.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

TRCE-1008

Message

Unable to load trace parameters.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the active control processor (CP) is unable to read the stored trace parameters.

Recommended

Action

Reboot the CP (dual-CP system) or restart the switch.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

TRCE-1009

Message

Unable to alert active MM that a dump has occurred.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the control processor (CP) is unable to communicate trace information to active CP. This
message is only applicable to bladed switches.

Recommended

Action

Execute the haShow command to verify that the current management module is standby and the active
management module is active.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.