TRCE-1007
5
TRCE-1007
Message
Notification of this MM has failed. Parameters temporarily out of sync with other
MM.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the active control processor (CP) is unable to alert the standby CP of a change in trace
status. This message is only applicable to bladed switches.
Recommended
Action
This message is often transitory. Wait a few minutes and try the command again.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
TRCE-1008
Message
Unable to load trace parameters.
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates that the active control processor (CP) is unable to read the stored trace parameters.
Recommended
Action
Reboot the CP (dual-CP system) or restart the switch.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
TRCE-1009
Message
Unable to alert active MM that a dump has occurred.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the control processor (CP) is unable to communicate trace information to active CP. This
message is only applicable to bladed switches.
Recommended
Action
Execute the haShow command to verify that the current management module is standby and the active
management module is active.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.