Em-1017, Em-1018, Em-1019 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 326

304
Fabric OS Message Reference
53-1003140-01
EM-1017
5
EM-1017
Message
Uncommitted WWN change detected. Cold reboot required.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that a user did not commit a changed World Wide Name (WWN) value before performing a
system restart, power cycle, or firmware download operation.
Recommended
Action
Change and commit the new WWN value.
EM-1018
Message
CP blade in slot code>/ Message Type FFDC | LOG Severity CRITICAL Probable Cause Indicates that there was a failure to read the chassis type from the system. Recommended Action Verify that the control processor (CP) blade is operational and is properly seated in its slot. EM-1019 Message Current chassis configuration option ( is not compatible with standby firmware version (Pre 4.4), cannot allow HA Sync. Message Type LOG Severity WARNING Probable Cause Indicates that the current chassis configuration option is not supported by the firmware on the standby Recommended Action Change the chassis configuration option to 1 using the chassisConfig command, or upgrade the
control processor (CP). This is true even if the standby CP comes up and is operational. High availability
(HA) synchronization of the CPs will not be allowed.
firmware on the standby CP to the version running on the active CP.