876

Fabric OS Message Reference

53-1003140-01

SSMD-1007

5

SSMD-1007

Message

Error while removing ACL from interface .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that an error occurred while programming a TCAM entry on the specified interface.

Recommended

Action

Try again after some time. If the problem persists, execute the supportSave command and then restart
or power cycle the switch.

SSMD-1008

Message

Apptype TCAM Table full for Slot: chip:.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the application type TCAM table is full on the specified chip.

Recommended

Action

Remove the unused protocol-based VLAN classifiers and Layer 2 extended access control lists (ACLs).

SSMD-1200

Message

QoS failed programming ASIC / Multicast Rate

Limit.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that DCE SSM encountered an unexpected error in programming the dataplane
application-specific integrated circuit (ASIC) for enforcing the Multicast Rate Limit feature.

Recommended

Action

Delete and reapply the Quality of Service (QoS) Multicast Rate Limit policy using the qos rcv-queue
multicast rate-limit
command.